Mechanical Properties and Tribological Behaviour of Retrieved UHMWPE Tibial Insert in Total Knee Replacement after Implantation 30 Months
نویسندگان
چکیده
Ultra high molecular weight polyethylene (UHMWPE) has been used as a load bearing and articulating counter face in total knee replacement (TKR) for over forty years1. However, wear debris generation of UHMWPE materials after their implantation in the human body has been proven to induce osteolysis and aseptic loosening, which is the main cause of long-term failure of TKR composed of UHMWPE and hard patella balls2-4. The relationships between the mechanical behaviour of UHMWPE and the long-term clinical performance of TKR component bearings remain poorly understood; therefore the reliable prediction of the wear performance of UHMWPE in human body has been a challenge for artificial joint materials study5. After implantation, the UHMWPE material will bear the multi-directional sliding friction and dynamic load in body fluid immersion; this is a black box of biotribology of joint implants in physiological environments which results in the reduction of the wear resistance of UHMWPE liners associated with mechanical failure6-8 and chemical degradation9-11. For this reason, previous studies focused their attention on the degradation mechanism of UHMWPE12-14, accelerated aging for degradation simulation15-19, the correlation between the mechanical behaviour of polymeric biomaterials and their wear performance in a knee simulator20-24.
منابع مشابه
Effects of Tibial Insert Slope on Polyethylene Wear and Stress
INTRODUCTION: Both posterior stabilized (PS) and cruciate retaining (CR) total knee replacement systems have demonstrated high rates of survivorship, high clinical knee scores and high patient satisfaction scores for decades. However, CR total knees sometimes exhibit more varied kinematics and a smaller range of motion than similar PS knees. Many factors can cause this, but one important factor...
متن کاملInvestigation of Wear Behavior of Biopolymers for Total Knee Replacements Through Invitro Experimentation
The average life span of knee prosthesis used in Total Knee Replacement (TKR) is approximately 10 to 15 years. Literature indicates that the reasons for implant failures include wear, infection, instability, and stiffness. However, the majority of failures are due to wear and tear of the prosthesis. The most common biopolymer used in TKR is Ultra High Molecular Weight Polyethylene (UHMWPE). Pr...
متن کاملComputational wear prediction of a total knee replacement from in vivo kinematics.
Wear of ultra-high molecular weight polyethylene bearings in total knee replacements remains a major limitation to the longevity of these clinically successful devices. Few design tools are currently available to predict mild wear in implants based on varying kinematics, loads, and material properties. This paper reports the implementation of a computer modeling approach that uses fluoroscopica...
متن کاملMobile or fixed unicompartmental knee prostheses? In-vitro wear assessments to solve this dilemma.
The unicompartmental knee prosthesis is an attractive alternative to total knee arthroplasty. Current UKP devices can be subdivided into two groups based on different design principles: fixed bearing knees, where the ultra-high molecular weight polyethylene meniscal component snap or press fits into the tibial tray, and mobile bearing designs which facilitate movement of the insert relative to ...
متن کاملThe effect of insert conformity and material on total knee replacement wear
The mean average life is increasing; therefore, there is a need to increase the lifetime of the prostheses. To fulfil this requirement, new prosthetic designs and materials are being introduced. Two of the design parameters that may affect wear of total knee replacements, and hence the expected lifetime, are the insert conformity and material. Computational models have been used extensively for...
متن کامل