Improving lactate analysis with the YSI 2300 GL: hemolyzing blood samples makes results comparable with those for deproteinized whole blood.

نویسندگان

  • P Foxdal
  • Y Bergqvist
  • S Eckerbom
  • B Sandhagen
چکیده

To obviate the well-documented problem of hematocrit dependency of the Yellow Springs Instruments (YSI) whole-blood lactate analyzer, we modified the dilution buffer by including a lysing reagent. This makes the results comparable with those of methods performed with deproteinized whole-blood samples. No centrifugation step is needed, thus preserving the convenience of the YSI instrument for stat and field use. The modification works equally well on plasma samples. Lactate concentrations measured in nonhemolyzed whole blood are not comparable with results for hemolyzed whole blood or protein-precipitated whole blood. We therefore recommend to all users of YSI equipment to lyse the erythrocytes before lactate determinations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lactate measured in diluted and undiluted whole blood and plasma: comparison of methods and effect of hematocrit.

We evaluated a new analyzer that measures lactate in undiluted whole blood by direct (or undiluted) amperometry [Nova Stat Profile 7 Analyzer (SP7); Nova Biomedical, Waltham, MA] by comparing it with two other analyzers, one for measuring lactate in whole blood by indirect (or diluted) amperometry [Model 2300; Yellow Springs Instrument Co. (YSI), Yellow Springs, OH] and another for measuring la...

متن کامل

Computed exercise plasma lactate concentrations: A conversion formula

OBJECTIVES Blood lactate measurements are common as a marker of skeletal muscle metabolism in sport medicine. Due to the close equilibrium between the extracellular and intramyocellular space, plasma lactate is a more accurate estimate of muscle lactate. However, whole blood-based lactate measurements are more convenient in field use. The purpose of this investigation was therefore (1) to estab...

متن کامل

Comparison of methods for the rapid laboratory assessment of children with malaria.

Rapid diagnosis and accurate quantification of Plasmodium falciparum parasitemia are important for the management of malaria. The assessment of disease severity also depends on evaluation of metabolic indexes such as blood glucose and lactate concentrations. Here we describe an accurate and rapid alternative to conventional thick film examination (Lambaréné method). We also assess near-patient ...

متن کامل

FreeStyle Mini blood glucose results are accurate and suitable for use in glycemic clamp protocols.

OBJECTIVE We assessed the accuracy of the FreeStyle Mini (FSM) meter for use in glycemic clamp and meal protocols in comparison with the HemoCue Glucose 201 DM Analyzer (HemoCue) and the YSI 2300 STAT Glucose Oxidase Analyzer (YSI). METHODS Seven volunteers with type 2 diabetes mellitus, 35-69 years old, underwent a frequently sampled meal test and a graded hyperglycemic test, on two separate...

متن کامل

A method-comparison study regarding the validity and reliability of the Lactate Plus analyzer

OBJECTIVES The aims of this study were to: (1) determine the validity and reliability of the Nova Biomedical Lactate Plus portable analyzer, and quantify any fixed or proportional bias; (2) determine the effect of any bias on the determination of the lactate threshold and (3) determine the effect that blood sampling methods have on validity and reliability. DESIGN In this method comparison st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 38 10  شماره 

صفحات  -

تاریخ انتشار 1992