Anterior Segment Intraocular Lens
نویسنده
چکیده
Currently, posterior chamber intraocular lenses (IOLs) correct totally or partially spherical aberrations. In this article we present the visual results of a prospective multicentre study evaluating the Micro AY IOL correcting 0.11μm of spherical aberration, which is a good compromise between optimal vision and a consistent depth of focus. We evaluated 124 eyes that were operated on using bi-manual micro-cataract surgery (BiMICS: 75%) or co-axial micro-cataract surgery (CoMICS: 25%) phacoemulsification with insertion of a Micro AY IOL through a 1.8–2.2mm incision. Mean post-operative best corrected visual acuity was 0.97±0.25; pre-operative spherical aberrations were +0.24±0.13μm, and reached +0.10±0.11μm post-operatively. There were no complications due to the lens, and photopic contrast sensitivity reached high levels.
منابع مشابه
Refractive Error and Anterior Segment Parametric Changes in Patients with Posterior Capsular Opacification after Nd: YAG Laser Posterior Capsulotomy
Background and Objective: Cataract is one of the most common causes of blindness in the world, and posterior capsular opacification (PCO) is the most common complication after cataract surgery. Nd: YAG laser posterior capsulotomy is a standard method for the treatment of PCO. The aim of this study was to investigate the effects of Yas laser capsulotomy on anterior segment parameters and lenticu...
متن کاملFulminant Panuveitis following Iris Suture Fixation of Posterior Chamber Intraocular Lens
We present a case of fulminant panuveitis following iris suture fixation of a posterior chamber intraocular lens. We hypothesize that the zonular dehiscence allowed the inflammatory cells in the anterior compartment to gain access to the posterior segment mimicking endophthalmitis or toxic anterior segment syndrome. Also certain bulky lens designs, like the current Rayner hydrophilic acrylic le...
متن کاملContact between 3 phakic intraocular lens models and the crystalline lens: an anterior chamber optical coherence tomography study.
Three phakic intraocular lens (IOL) models were implanted in 3 different patients. With the usual slitlamp examination, it was not possible to determine whether there was contact between the IOLs and the natural crystalline lens. Using the anterior chamber optical coherence tomography (AC OCT) scanner, direct contact between the natural crystalline lens and the 3 phakic IOLs was revealed. A dyn...
متن کاملSpontaneous dislocation of lens bag with acrylic lens after uneventful cataract surgery – unusual complication of cataract surgery
INTRODUCTION Spontaneous dislocation of intraocular lens with bag is rare. METHODS We report a case of a 56-year-old male who presented with spontaneous anterior dislocation of an in-the-bag intraocular lens 3 years after manual small incision cataract surgery. He had undergone manual small incision cataract surgery with foldable acrylic intraocular lens implantation, and 18 months after cata...
متن کاملMeasurement of combined corneal, internal, and total ocular optical quality analysis in anterior segment pathology with the OPD-scan and OPD-station.
PURPOSE To show the clinical use of the NIDEK OPD-Scan wavefront aberrometer and OPD-Station software in anterior segment surgery and pathology. METHODS Case examples are presented along with discussion about the relevant clinical data obtained from the OPD-Scan and OPD-Station software. RESULTS Six case examples including cataract surgery, secondary IOL implantation, phakic intraocular len...
متن کاملToxic Anterior Segment Syndrome after Foldable Artiflex Iris-Fixated Phakic Intraocular Lens Implantation
Toxic anterior segment syndrome (TASS) developed in four cases after uneventful implantation of a foldable iris-fixated phakic intraocular lens (pIOL). Two cases occurred sequentially in one patient. The TASS subsided without complications in all cases after intensive topical steroid treatment. A multitude of possible causes is considered for the occurrence of these TASS cases. From the sterili...
متن کامل