A comparison of ML Flow serology and slit skin smears to assess the bacterial load in newly diagnosed leprosy patients in Brazil.

نویسندگان

  • Sandra Lyon
  • Ana Claudia Lyon
  • Rozana Castorina Da Silva
  • Maria Aparecida De Faria Grossi
  • Silvia Helena Lyon
  • Samira Bührer-Sékula
  • Manoel O C Rocha
چکیده

INTRODUCTION The ML Flow test is an immunochromatographic assay that detects IgM antibodies against M. leprae-specific anti-phenolic glycolipid I (PGL-I). In addition to slit skin smears stained by the Ziehl-Neelsen technique, it can be helpful in the operational classification of leprosy patients for treatment purposes. OBJECTIVE This work studied the relationship between antibody levels as detected by semi-quantitative ML Flow serologic test and bacterial load as quantified by slit skin smear. PATIENTS AND METHODS 135 patients with newly detected leprosy at the reference service in Sanitary Dermatology in Brazil had slit skin smears (registered as bacillary index - BI) and an ML Flow test (registered qualitatively and semi-quantitatively) performed at admission. A logistic regression and agreement measures (kappa index) were calculated. RESULTS Slit skin smears were positive in 35.9% of patients and 57% of patients were seropositive for PGL-1 antibodies. Among the seropositive patients, 416% had five or fewer skin lesions, and 65.8% had more than one peripheral nerve involved. Slit skin smears were positive in only three seronegative patients (5.6%), and negative in 41.9% of seropositive patients. Patients with a BI of 4 + had an OR of 33 for being seropositive in comparison to those with a low BI. CONCLUSIONS There is a correlation between serologic test and slit skin smear results. Therefore, an ML Flow test may become a useful tool in the clinical classification of leprosy, besides slit skin smears, which require a proper laboratory infrastructure and experienced personnel.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The ML flow test as a point of care test for leprosy control programmes: potential effects on classification of leprosy patients.

OBJECTIVE To evaluate the use of the ML Flow test as an additional, serological, tool for the classification of new leprosy patients. DESIGN In Brazil, Nepal and Nigeria, 2632 leprosy patients were classified by three METHODS : (1) as multibacillary (MB) or paucibacillary (PB) according to the number of skin lesions (WHO classification), (2) by slit skin smear examination, and (3) by serolo...

متن کامل

Use of the ML-Flow test as a tool in classifying and treating leprosy.

BACKGROUND The treatment of leprosy is defined by the classification of patients as paucibacillary (PB) or multibacillary (MB). The WHO (World Health Organization) classifies patients according to the number of lesions, but Ridley-Jopling (R & J) also uses complementary exams, which are difficult to use outside reference services. In 2003, a test called ML-Flow, an alternative to Elisa serology...

متن کامل

Factors associated with ML Flow test seropositivity in leprosy patients and household contacts under the age of 18.

This article presents the results of a cross-sectional study involving 115 newly-diagnosed leprosy patients and 1,011 household contacts, all under the age of 18. Seropositivity ratios and factors associated with a positive ML Flow were determined. The test was positive in 21.7% of patients and in 19.7% of contacts. Among patients, logistic regression indicated the association of seropositivity...

متن کامل

Association of the ML Flow serological test with slit skin smear Associação do teste sorológico ML Flow com a baciloscopia

A descriptive, exploratory study was conducted analyzing the association of covariables in the results of the ML Flow serological test and slit skin smear. A total of 60 leprosy cases diagnosed at the state Sanitary Dermatology Referral Center were investigated. Slit skin smear samples were collected from four sites and the results were expressed by the bacillary index. ML Flow was registered i...

متن کامل

Bacterial index of granuloma and its relevance compared to BI of skin smears.

Editor, The importance of accurate histopathological assessment of type of leprosy with the help of skin biopsy is emphasized by the widespread poor performance of slit skin smears (SSS). Many workers have reported ®nding AFB more frequently in skin biopsies compared with slit skin smears in all types of leprosy. However, the presence of AFB in skin biopsy has been assigned no role in grading o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Leprosy review

دوره 79 2  شماره 

صفحات  -

تاریخ انتشار 2008