Collimators with adjustable jaws are used in the SLC linac, arcs, and final focus to eliminate the tails of the beams that produce backgrounds in the SLD detectors. However, if the beams are not centered within the jaws of the collimators, transverse wakefields are generated which act to increase the beam emittances. The sensitivity to the beam offset is largest in the vertical collimators in the linac where the small beam sizes (< 100 pm) require that the gap between the jaws be reduced to about a millimeter for effective background reduction. GL4 lb
منابع مشابه
Measurement of Resistivity Dominated Collimator Wakefield Kicks at the Slc
Collimation of the multi-MW beams in present linear collider designs is a critical issue. Graphite as a possible collimator material exhibits good mechanical properties but a rather poor electrical conductivity. The resulting resistive wakefields can potentially deteriorate the beam quality. The knowledge of strength and scalings of such wakefields is essential for the design of the collimation...
متن کاملCollimator Wakefield Calculations for ILC-TRC Report
We summarize the formalism of collimator wakefields and their effect on beams that are near the center of the collimator gap, and apply the formalism to the TESLA, NLC, and CLIC collimation systems. Collimator Wakefield Calculations for ILC-TRC Report
متن کاملNumerical Calculations of Short-range Wakefields of Collimators
The performance of future linear colliders are limited by the effect of short-range collimator wakefields on the beam. The beam quality is sensitive to the positioning of collimators at the end of the linac. The determination of collimator wakefields has been difficult, largely because of the scarcity of measurement data, and of the limitation of applicability of analytical results to realistic...
متن کاملMonte Carlo Study of Unflattened Photon Beams Shaped by Multileaf Collimator
Introduction: This study investigates basic dosimetric properties of unflattened 6 MV photon beam shaped by multileaf collimator and compares them with those of flattened beams.Materials and Methods: Monte Carlo simulation model using BEAM code was developed for a 6MV photon beam based on Varian Clinic 600 unique performance linac operated with and without a flattening filter in beam line. Dosi...
متن کاملMonte Carlo Simulation of Electron Beams produced by LIAC Intraoperative Radiation Therapy Accelerator
Background: One of the main problems of dedicated IORT accelerators is to determine dosimetric characteristics of the electron beams. Monte Carlo simulation of IORT accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry.Materials and Methods: Liac accelerator head was modeled using the BEAMnrcMonte Carlo simulation system. Phase-space files were generated at...