A simple, direct radioimmunoassay for plasma cortisol, featuring a 125I radioligand and a solid-phase separation technique.
نویسندگان
چکیده
A simple, direct radioimmunoassay for cortisol in human serum and plasma is described. An antiserum, raised in sheep to a cortisol-3-(O-carboxymethyl)oxime/bovine serum albumin conjugate, is coupled to microcellulose. No extraction is required because plasma samples and standards are incubated with the antiserum and an 125I radioligand in a low-pH buffer, which denatures cortisol-binding globulins. The assay satisfies accepted validation criteria. In addition, results from the radioimmunoassay compare well with those obtained by a gas chromatographic-mass spectrometric technique (r = 0.968; FRIA = 0.97 FGCMS + 2.0 nmol/L). The latter procedure features the very high intrinsic specificity obtained by selected ion monitoring at high mass-spectrometric resolution (M/deltaM = 8500) with a Varian MAT-731 instrument. The simplicity of the radioimmunoassay procedure, with use of reagents prepared "in house," makes this a very practical and economical assay for use in the medium or large endocrine laboratory.
منابع مشابه
A strategy for radioimmunoassay of plasma progesterone with use of a homologous-site 125I-labeled radioligand.
In this sensitive, specific 125I radioimmunoassay for plasma progesterone, an identical glucuronide bridge is used in the immunogen and radioligand. This apparently provides a system in which the bridge is poorly recognized and thereby avoids the excessively high affinity of the tracer for the antiserum and the consequent poor sensitivity that commonly is found in other homologous-bridge situat...
متن کاملOne-step synthesis of a cortisol derivative for radioiodination and application of the 125I-labeled cortisol to radioimmunoassay.
A one-step synthesis of a cortisol derivative for radioiodination is presented. The radioimmunoassay for cortisol using the bridge heterologous 125I-labeled antigen was more sensitive than that using a bridge homologous antigen. Cortisol levels in saliva and serum were easily determined by direct radioimmunoassay with the proposed 125I-labeled antigen.
متن کاملReview of preconcentration and solid phase extraction for the determination of trace Lead
Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...
متن کاملReview of preconcentration and solid phase extraction for the determination of trace Lead
Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...
متن کامل125I radioimmunoassay of delta-9-tetrahydrocannabinol in blood and plasma with a solid-phase second-antibody separation method.
In this sensitive and specific radioimmunoassay for delta-9-tetrahydrocannabinol, an iodinated tracer with high specific activity and a solid-phase separation are used. Within-run coefficients of variation for 5.0 and 30.0 microgram/L concentrations were 7.8 and 4.2% for plasma and 14 and 10.6% for hemolyzed blood specimens, respectively. Day-to-day coefficients of variations ranged from 7.3 to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 25 5 شماره
صفحات -
تاریخ انتشار 1979