Evaluation of an automated preanalytical robotic workstation at two academic health centers.
نویسندگان
چکیده
BACKGROUND Purchase of automated systems in today's clinical laboratory needs justification based on demonstrable improvements in efficiency and a sound payback model. Few studies provide information on laboratory automation that focuses on the preanalytical portion of specimen processing. METHODS We recently evaluated an automated preanalytical processing unit (GENESIS FE500) at two academic health centers. This preanalytical unit processes blood specimens through automated specimen sorting, centrifugation, decapping, labeling, aliquoting, and placement of the processed specimen in the analytical rack. We quantified the output of the FE500 by processing >3000 barcode-labeled specimens according to a protocol designed to test all of the features of this automated specimen-processing unit. RESULTS Depending on the batch size, aliquot number requested, and percentage of tubes that required centrifugation, the mean system output performance varied between 93 and 502 total tubes/h. Throughput increased when the batch size expanded from 40 or 100 samples (mean = 211 total tubes processed/h) to batch sizes of 200 and 300 tubes (mean = 474 total tube processed/h). The GENESIS FE500 processed specimen tubes differing in size from 13 x 65 mm (width x height) to 16 x 100. At one site, the FE500 was operated by one person, compared with the three individuals required to perform the same tasks manually. Finally, the specimen-processing error rate determined at one of the institutions was significantly reduced. CONCLUSIONS We conclude that the GENESIS FE500 effectively reduces the labor associated with specimen processing; decreases the number of laboratory errors that occur with specimen sorting, labeling, and aliquoting; and improves the integrity of specimen handling throughout the steps of specimen processing.
منابع مشابه
Automated classification of pulmonary nodules through a retrospective analysis of conventional CT and two-phase PET images in patients undergoing biopsy
Objective(s): Positron emission tomography/computed tomography (PET/CT) examination is commonly used for the evaluation of pulmonary nodules since it provides both anatomical and functional information. However, given the dependence of this evaluation on physician’s subjective judgment, the results could be variable. The purpose of this study was to develop an automated scheme for the classific...
متن کاملThe Evaluation of Error Types and Turnaround Time of Preanalytical Phase in Biochemistry and Hematology Laboratories
Background& Objective: Each laboratory should determine the type of errors and turnaround time (TAT), especially in the preanalytical phase to report quality and timeliness of the test results. The current study aimed at investigating the common causes of preanalytical errors in biochemistry and hematology laboratories and evaluating the preanalytical ...
متن کاملSemiautomated DNA mutation analysis using a robotic workstation and molecular beacons.
BACKGROUND Our increasing knowledge of the genetic basis of inheritable diseases requires the development of automated reliable methods for high-throughput analyses. METHODS We investigated the combination of semiautomated DNA extraction from blood using a robotic workstation, followed by automated mutation detection using highly specific fluorescent DNA probes, so-called molecular beacons, w...
متن کاملThe transition to automated practitioner order entry in a teaching hospital: the VA Puget Sound experience
We recently installed an automated practitioner order entry system on our busiest inpatient wards and critical care units. The installation followed 20 months preparation in which we created the workstation, network, and host infrastructure, developed requisite policies, recruited personnel to support the system, and installed the software in areas where the pace of order entry was less intense...
متن کاملDesign, Evaluation and Prototyping of a New Robotic Mechanism for Ultrasound Imaging
This paper presents a new robotic mechanism for ultrasound imaging. The device is placed on a patient's body by an operator, and an ultrasound expert controls the motions of the device to obtain ultrasound images. The paper focuses on the robotic mechanism that performs ultrasound imaging. The design of the mechanism is based on two approaches to produce center of motion for an ultrasound probe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 48 3 شماره
صفحات -
تاریخ انتشار 2002