Percutaneous closure of ductus arteriosus with the amplatzer prosthesis. The Brazilian experience.

نویسندگان

  • L C Simões
  • C A Pedra
  • C A Esteves
  • R Camargo
  • S L Braga
  • P Loureiro
  • M A Santos
  • V F Fontes
چکیده

OBJECTIVE - To report the results of percutaneous occlusion of persistent ductus arteriosus with the Amplatzer prosthesis in 2 Brazilian cardiological centers. METHODS - From May 1998 to July 2000, 33 patients with clinical and laboratory diagnosis of persistent ductus arteriosus underwent attempts at percutaneous implantation of the Amplatzer prosthesis. The median age was 36 months (from 6 months to 38 years), and the median weight was 14kg (from 6 to 92kg). Sixteen patients (48.5%) were under 2 years of age at the time of the procedure. All patients were followed up with periodical clinical and echocardiographic evaluations to assess the presence and degree of residual shunt and possible complications, such as pseudocoarctation of the aorta and left pulmonary artery stenosis. RESULTS - The minimum diameter of the arterial ducts ranged from 2.5 to 7.0mm (mean of 4.0+/-1.0, median of 3.9). The rate of success for implantation of the prosthesis was 100%. Femoral pulse was lost in 1 patient. The echocardiogram revealed total closure prior to hospital discharge in 30 patients, and in the follow-up visit 3 months later in the 3 remaining patients. The mean follow-up duration was 6.4+/-3.4 months. All patients were clinically well, asymptomatic, and did not need medication. No patient had narrowing of the left pulmonary artery or of the aorta. No early or late embolic events occurred, nor did infectious endarteritis. A new hospital admission was not required for any patient. CONCLUSION - The Amplatzer prosthesis for persistent ductus arteriosus is safe and highly effective for occlusion of ductus arteriosus of varied diameters, including large ones in small symptomatic infants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Right patent ductus arteriosus with an ipsilateral aortic arch: percutaneous closure with amplatzer devices].

The association of a right aortic arch with an ipsilateral patent ductus arteriosus is rare, especially when there are no other intracardiac anomalies. We report three female patients aged 26, 35 and 9 years with this combination in whom previous attempts at surgical closure by thoracotomy and sternotomy were unsuccessful and who subsequently underwent successful percutaneous closure of the def...

متن کامل

Evaluating the Clinical Course of Patent Ductus Arteriosus after Discharge and Comparing in Therapies Techniques

Background Patent ductus arteriosus is an open channel between the aorta and pulmonary artery. The study aimed to evaluate the clinical course of patent ductus arteriosus after discharge and comparing in therapies technique. Materials and Methods This cross-sectional and inferential- descriptive study was performed in the hospitals of city of Zahedan-Iran in the period of one decade from 2005 ...

متن کامل

Percutaneous Forceps Retrieval of an Embolized Amplatzer Duct Occluder

Transcatheter closure of patent ductus arteriosus with the Amplatzer duct occluder shows excellent results. However, there is a risk of device embolization after deployment. We report the case of a 33-year-old man in whom an embolized Amplatzer device was retrieved from the right pulmonary artery by a percutaneous method. We also review this uncommon severe complication and offer technical tips...

متن کامل

Complementary Techniques of Percutaneous Closure of Ductus Arteriosus Using Detachable Cook Coils and Amplatzer Devices.

BACKGROUND Patent Ductus Arteriosus (PDA) is a commoncardiac malformation whose treatment locally has been surgical ligation via a lateral thoracotomy. Device closure of the ductus was first performed at the Mater hospital in 1999 in a ten year old male using a five millilitre detachable cook coil. In 2000 the Amplatzer device was introduced to close larger ducts. Subsequently these devices hav...

متن کامل

Transcatheter closure of the patent ductus arteriosus using an Amplatzer duct occluder in adults.

Patent ductus arteriosus (PDA) is a congenital heart disease that frequently escapes detection until the patient reaches adulthood. Percutaneous closure of the PDA has been established as a safe alternative to surgery, the Amplatzer duct occluder (ADO) is a new device that has been recently reported in paediatric patients. Our initial experience with an of ADO in an adult population appears to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de cardiologia

دوره 77 6  شماره 

صفحات  -

تاریخ انتشار 2001