Jailing Technique Using a Catheter-based Open-cell Stent System in Internal Carotid Artery Sidewall Aneurysms Unfeasible to Simple Coiling
نویسندگان
چکیده
OBJECTIVE An open cell stent system may offer better apposition of cell struts to vessel wall than a closed cell stent system in acute vasculature. The purpose of this study was to evaluate the feasibility of coiling using the jailing technique with the Neuroform EZ stent system. METHODS The jailing technique using the open-cell stent system of the Neuroform EZ stent was planned in 22 consecutive patients with 22 cerebral aneurysms. We retrospectively evaluated the technical success of the jailing technique and the occurrence of interference between two microcatheters as well as the factors influencing this interference. RESULTS The jailing technique was successful in 19/22 patients (86.4%), and interference between two microcatheters occurred in 6/21 (28.6%). The jailing technique failed in 3/22 patients, with problems that included failure of the stent delivery system to advance into the positioned microcatheter in one, interference between the microcatheters during the advancement of the stent delivery system in one, and failure of microcatheter insertion into the aneurysm sac in the remaining patient. Interference between the two microcatheters developed during the advance of the stent delivery system into the positioned microcatheter in all cases. One factor that influences interference between two microcatheters more than expected by chance is the carotid siphon angle (p = 0.019). CONCLUSION The acuteness of the carotid siphon angle influences the interference between two microcatheters. Therefore, the jailing technique using the Neuroform EZ stent should be performed carefully in cerebral aneurysms with an acute carotid siphon angle because the procedure may possibly fail.
منابع مشابه
Aneurysm ostium angle: a predictor of the need for stent as assistance for endovascular aneurysm coiling in internal carotid artery sidewall aneurysms.
BACKGROUND AND PURPOSE There is no satisfactory parameter that can predict the need for assistant devices for endovascular aneurysm coiling. Our aim was to evaluate the utility of MOA as a predictor of the need for stent-assisted coiling in ICA sidewall aneurysms. MATERIALS AND METHODS From a retrospective review of an internal data base, 55 consecutive ICA sidewall aneurysms were identified....
متن کاملThe Interference Phenomenon of Microcatheters in the Jailing Treatment for Internal Carotid Artery Side Wall Aneurysms with an Open Cell Stent System
OBJECTIVE Excelsior XT-27 (Stryker Neurovascular, Fremont, CA, USA) or Rebar 27 (eV3 Covidien, Irvine, CA, USA) microcatheters have recently been used to overcome the limitations of the Renegade Hi-Flo microcatheter such as interference between two microcatheters (one for stent delivery and the other for cerebral aneurysm coiling) during the jailing technique. We evaluated differences and influ...
متن کاملSurgical extraction of migrated coils via proximal segment of the anterior cerebral artery: an emergency alternative.
Coil migration is a severe complication in endovascular treatment. We report our experience of prompt surgical extraction of migrated coils via excised proximal A1 following endovascular embolization of intracranial aneurysms in two patients. Both patients had to undergo coiling or stent-assisted coiling for cerebral aneurysms, and while operating the coils protruded and migrated to the bifurca...
متن کاملThe Treatment of Large and Giant Paraclinoid Internal Carotid Artery Aneurysms
Paraclinoid internal carotid artery aneurysms originate from the internal carotid artery between the distal dural ring and the posterior communicating artery. Surgical treatment of these aneurysms is technically challenging because of the surrounding neurovascular structures. There are several ways to treat these lesions: direct clipping with retrograde suction decompression, endovascular coili...
متن کاملBalloon-assisted guide catheter positioning to overcome extreme cervical carotid tortuosity: technique and case experience
BACKGROUND AND SIGNIFICANCE We describe a method by which to efficiently and atraumatically achieve distal positioning of a flexible guiding catheter beyond extreme cervical tortuosity using a hypercompliant temporary occlusion balloon. METHODS A retrospective review of a prospective neuroendovascular database was used to identify cases in which a hypercompliant balloon catheter (Hyperform or...
متن کامل