Microvolumetric Respirometry
نویسندگان
چکیده
When the Arctic Research Laboratory at Point Barrow, Alaska, was ready for use in 1947, it was late autumn. Frost could set in at any time and render unavailable precious material for our projected respiratory studies. This situation brought about an acute need for many more micro respirometers than the dozen we had, and prompted the construction of simple, plastic respirometers drilled in blocks of lucite. Standard specimen vials attached by rubber stoppers were used as respiration and compensating vessels and tuberculin syringes for the measurements of the oxygen consumption (Scholander, 1950). In a few days our Eskimo friends made enough new respirometers to fill our needs. A micro model was similarly constructed and both sizes proved eminently useful on a wide variety of animal and plant material. A model for tissue respiration was designed using standard Warburg vessels. Wennesland (1949) at the same laboratory modified this design to contain an internal rod chamber. The present respirometers are a further development of the "Barrow respirometers" which are all based on the volumetric principle introduced by Winterstein (1912, 1913). In the volumetric system, the pressure is maintained constant, and the volume changes are*read directly. The principle involved can be stated as follows: The pressure of the respiration chamber is balanced against a compensating chamber through a manometer. As gas is absorbed or evolved, it is exactly compensated for by a volumetric device so as to maintain pressure balance with the compensating chamber. The change in gas volume is measured directly on the volumetric device. The volumetric system offers some conspicuous advantages. The volume changes are read directly as such, and are independent of the gas volume of the apparatus. The only calibrated part is the compensating device (piston 375
منابع مشابه
Accurate continuous drug delivery at low infusion rate with a novel microvolumetric infusion pump (MVIP): pump design, evaluation and comparison to the current standard.
Infusion devices for continuous and precise drug administration are indispensable tools in anaesthesia and critical care medicine. Problems such as start-up delays, non-continuous flow and susceptibility to hydrostatic pressure changes at low infusion rates resulting in accidental bolus release or prolonged flow interruption are inherent to current infusion technology. In order to improve preci...
متن کاملFinding the best estimates of metabolic rates in a coral reef fish.
Metabolic rates of aquatic organisms are estimated from measurements of oxygen consumption rates ( ) through swimming and resting respirometry. These distinct approaches are increasingly used in ecophysiology and conservation physiology studies; however, few studies have tested whether they yield comparable results. We examined whether two fundamental measures, standard metabolic rate (SMR) and...
متن کاملThe power of feeder-mask respirometry as a method for examining hummingbird energetics.
Many birds spend important portions of their time and energy flying. For this reason, quantification of metabolic rates during flight is of crucial importance to understanding avian energy balance. Measurement of organismal gas exchange rates using a mask enclosing the whole head or respiratory orifices has served as an important tool for studying animal energetics because it can free the rest ...
متن کاملDietary effects on resting metabolic rate in C57BL/6 mice are differentially detected by indirect (O2/CO2 respirometry) and direct calorimetry
Resting metabolic rate (RMR) studies frequently involve genetically-manipulated mice and high fat diets (HFD). We hypothesize that the use of inadequate methods impedes the identification of novel regulators of RMR. This idea was tested by simultaneously measuring RMR by direct calorimetry and respirometry in C57BL/6J mice fed chow, 45% HFD, and then returned to chow. Comparing results during c...
متن کاملDirect calorimetry identifies deficiencies in respirometry for the determination of resting metabolic rate in C57Bl/6 and FVB mice.
Substantial research efforts have been aimed at identifying novel targets to increase resting metabolic rate (RMR) as an adjunct approach to the treatment of obesity. Respirometry (one form of "indirect calorimetry") is unquestionably the dominant technique used in the obesity research field to assess RMR in vivo, although this method relies upon a lengthy list of assumptions that are likely to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of General Physiology
دوره 35 شماره
صفحات -
تاریخ انتشار 1952