Mycobacterium fortuitum causing infection of a biventricular pacemaker/implantable cardioverter defibrillator.
نویسندگان
چکیده
Increased utilization of cardiovascular implantable electronic devices (CIED) has seen a corresponding rise in related infections. Non-tuberculosis mycobacteria (NTM) are rarely the cause. Treatment involves susceptibilities, antimicrobials, and device removal. This study presents a patient who underwent a biventricular implantable cardioverter defibrillator upgrade with a multi-drug resistant Mycobacterium fortuitum located at the pocket site and a lead infection.
منابع مشابه
Inappropriate shock and battery switching to "End of Life" in a patient with biventricular ICD during magnetic resonance imaging.
Presence of a cardiac pacemaker or implantable cardioverter defibrillator (ICD) is a relative contraindication to magnetic resonance imaging (MRI). Biventricular ICDs are often used in the treatment of advanced heart failure; however, reports on experience with biventricular ICDs are lacking in the literature. In this case report, we describe a pacemaker-dependent patient with a biventricular I...
متن کاملIs correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?
Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...
متن کاملPatient Report and Review of Rapidly Growing Mycobacterial Infection after Cardiac Device Implantation
Mycobacterial infections resulting from cardiac implantable electronic devices are rare, but as more devices are implanted, these organisms are increasingly emerging as causes of early-onset infections. We report a patient with an implantable cardioverter-defibrillator pocket and associated bloodstream infection caused by an organism of the Mycobacterium fortuitum group, and we review the liter...
متن کاملCandida glabrata Infection on Retained Implantable Cardioverter Defibrillator Lead in Heart Transplant Patient Requiring Redo Upper Mini-Sternotomy Approach
We present the first documented case of a Candida glabrata infection on the retained lead of a cardiovascular implantable electronic device (CIED) in an immunosuppressed heart transplant recipient. This is the first documented case of a redo upper mini-sternotomy approach for a lead removal and innominate vein reconstruction with bovine patch. The patient is a 55 year-old male with non-ischemic...
متن کاملTHE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of mycobacteriology
دوره 1 4 شماره
صفحات -
تاریخ انتشار 2012