A volume loading test for the detection of hypovolemia and dehydration.

نویسندگان

  • Robert G Hahn
  • Audrius Andrijauskas
  • Dan Drobin
  • Christer Svensén
  • Juozas Ivaskevicius
چکیده

BACKGROUND AND OBJECTIVES There is a need for simple method allowing detection of dehydration and hypovolemia. Based on a new theory of homeostatic blood states, we hypothesized that hemodilution following standardized crystalloid fluid bolus can be used to discriminate between baseline normohydration and dehydration, also normovolemia and hypovolemia. METHODS Computer simulations based on previously published kinetic data were used to define the best time points for discrimination between baseline normohydration and dehydration, also normovolemia and hypovolemia. Hemodilution was compared at the proposed timing in 20 volunteers who received 40 infusions of Ringer's solution of 25 mL/kg during 30 minutes. RESULTS Simulations indicated that preexisting hypovolemia could be best detected at the end of infusion, while dehydration 20-30 min later. In baseline hypovolemia, the peak reduction of hemoglobin concentration was 16.0% at the end of infusion, while it was only 11.8%, when participants were normovolemic (P<0.004). In baseline dehydration, the residual hemodilution was 8.6%, when measured 30 min after the end of infusion. It was only 3.1% in baseline normohydration (P<0.006). CONCLUSIONS In response to fluid load, the baseline dehydration exaggerates the lowering of residual hemoglobin in respect to baseline. Meanwhile, baseline hypovolemia exaggerates the lowering of peak hemoglobin concentration. The volume loading test that deploys interpretation of hemoglobin dynamics in response to the test volume load could possibly serve as an easily available guide to indicate an individual patient's baseline hydration state and volemia. The introduction of continuous noninvasive monitoring of hemoglobin concentration would expand the applicability of the new method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical aspects of the control of plasma volume at microgravity and during return to one gravity.

Plasma volume is reduced by 10-20% within 24-48 h of exposure to simulated or actual microgravity. The clinical importance of microgravity induced hypovolemia is manifested by its relationship with orthostatic intolerance and reduced maximal oxygen uptake (VO2max) after return to one gravity (1G). Since there is no evidence to suggest that plasma volume reduction during microgravity is associat...

متن کامل

Extravascular Lung Water Does Not Increase in Hypovolemic Patients after a Fluid-Loading Protocol Guided by the Stroke Volume Variation

Introduction. Circulatory failure secondary to hypovolemia is a common situation in critical care patients. Volume replacement is the first option for the treatment of hypovolemia. A possible complication of volume loading is pulmonary edema, quantified at the bedside by the measurement of extravascular lung water index (ELWI). ELWI predicts progression to acute lung injury (ALI) in patients wi...

متن کامل

Deterioration of left ventricular chamber performance after bed rest : "cardiovascular deconditioning" or hypovolemia?

BACKGROUND Orthostatic intolerance after bed rest is characterized by hypovolemia and an excessive reduction in stroke volume (SV) in the upright position. We studied whether the reduction in SV is due to a specific adaptation of the heart to head-down tilt bed rest (HDTBR) or acute hypovolemia alone. METHODS AND RESULTS We constructed left ventricular (LV) pressure-volume curves from pulmona...

متن کامل

Hyperglycemia-Induced Hypovolemia Is Involved in Early Cardiac Magnetic Resonance Alterations in Streptozotocin-Induced Diabetic Mice: A Comparison with Furosemide-Induced Hypovolemia

AIMS The aim of the study was to assess the early features of diabetic cardiomyopathy using cardiac magnetic resonance within the first week after streptozotocin injection in mice. We focused on the relationship between left ventricular function and hypovolemia markers in diabetic animals compared to a hypovolemic rodent model. METHODS AND RESULTS Swiss mice were randomized into control (grou...

متن کامل

Modifications of blood volume alter the disposition of markers of blood volume, extracellular fluid, and total body water.

Recirculatory pharmacokinetic models for indocyanine green (ICG), inulin, and antipyrine describe intravascular mixing and tissue distribution after i.v. administration. These models characterized physiologic marker disposition in four awake, splenectomized dogs while they were normovolemic, volume loaded (15% of estimated blood volume added as a starch solution), and mildly and moderately hypo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medicina

دوره 44 12  شماره 

صفحات  -

تاریخ انتشار 2008