Direct S-Parameter Extraction by Physical Two-Dimensional Device AC-Simulation

نویسنده

  • V Palankovski
چکیده

We present results from fully two-dimensional physical device simulation. Scattering parameters (S-parameters) are directly obtained from small-signal AC-analysis of real heterostructure devices. A comparison reveals very good agreement with measured data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Small-Signal Analysis and Direct S-Parameter Extraction

We present a comparison of several device parameters obtained by fully two-dimensional physical device simulation of several device parameters and measurements. Several features for direct extraction of either extrinsic or intrinsic (de-embedded) parameters sets from AC-simulation were implemented in the three-dimensional device simulator Minimos-NT [1]. The scattering parameters (S-parameters)...

متن کامل

Cell parameter extraction method for AC plasma display panels

This paper presents a cell parameter extraction method for three-electrode AC plasma display panels (PDPs). This method uses three different two-electrode AC discharges to extract the cell capacitances. The drive point capacitances of the cell with and without a two-electrode dark discharge were measured, and the cell capacitances were extracted from them. The extracted cell capacitances agree ...

متن کامل

Direct extraction feature for scattering parameters of SiGe-HBTs

We present a direct approach to obtain scattering parameters (S-parameters) and other derived figures of merit of SiGe-HBTs by means of small-signal (ac) analysis. Therefore, an additional simulation mode has been implemented in the three-dimensional device simulator MINIMOS-NT. Several additional features are provided for efficiently obtaining various small-signal parameters. The accuracy of t...

متن کامل

Three-dimensional characteristic approach for incompressible thermo-flows and influence of artificial compressibility parameter

In this paper the characteristics of unsteady three-dimensional incompressible flows with heat transfer are obtained along with artificial compressibility of Chorin. At first, compatibility equations and pseudo characteristics for three-dimensional flows are derived from five governing equations (continuity equation, Momentum equations in three directions, and energy equation) and then results ...

متن کامل

Non-Isolated Direct AC-DC Converter Design with BCM-PFC Circuit

D1 D2 S2 Abstract—This paper proposes two types of non-isolated direct AC-DC converters. First, it shows a buck-boost converter with an H-bridge, which requires few components (three switches, two diodes, one inductor and one capacitor) to convert AC input to DC output directly. This circuit can handle a wide range of output voltage. Second, a direct AC-DC buck converter is proposed for lower o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003