Background phase correction in phase contrast velocity encoded CMR reduces gender differences and improves the accuracy and precision of Qp/Qs

نویسندگان

  • Jannike Nickander
  • Magnus Lundin
  • Jonas Jenner
  • Eva Maret
  • Peder Sörensson
  • Andreas Sigfridsson
  • Martin Ugander
چکیده

Background Cardiovascular magnetic resonance (CMR) flow quantification for determining the ratio of flow between the pulmonary and systemic circulation (Qp/Qs) is used to quantify cardiac shunts. However, both the accuracy and precision of Qp/Qs can be influenced by measurement errors in flow quantification. Post-processing methods for stationary tissue background correction have been proposed to improve flow quantification accuracy. We sought to evaluate the changes in accuracy and precision of Qp/Qs following stationary tissue background correction. We hypothesized that stationary background correction would reduce the standard deviation (SD) of mean Qp/Qs compared to uncorrected measurements in clinical patients without cardiac shunts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Best precision in measuring Qp/Qs is achieved with quadratic, not linear, stationary tissue background correction in phase contrast velocity encoded CMR

Background Cardiovascular magnetic resonance (CMR) flow quantification for determining the ratio of flow between the pulmonary artery and aorta (Qp/Qs) is used to quantify cardiac shunts. Post-processing methods, including linear or quadratic stationary tissue background correction have been proposed to improve accuracy and precision in flow quantification. However, it is not known which method...

متن کامل

Baseline correction of phase contrast images improves quantification of blood flow in the great vessels.

PURPOSE Phase-contrast Cardiovascular Magnetic Resonance Imaging (CMR) generally requires the analysis of stationary tissue adjacent to a blood vessel to serve as a baseline reference for zero velocity. However, for the heart and great vessels, there is often no stationary tissue immediately adjacent to the vessel. Consequently, uncorrected velocity offsets may introduce substantial errors in f...

متن کامل

Comparison of Two Methods for Correcting Baseline Offset Error in Phase-Contrast MR Imaging

Background Phase-contrast MRI (PC-MRI) can be used to assess valvular heart diseases. It can also measure pulmonarysystemic flow ratio (Qp/Qs) and help identify intracardiac shunts. However, phase offsets in PC-MRI caused by main field inhomogeneity and eddy-current introduce baseline offset errors in flow quantification and hence Qp/Qs. This error can be corrected by surface-fitting [1] or usi...

متن کامل

Baseline correction of phase-contrast images in congenital cardiovascular magnetic resonance

BACKGROUND One potential source of error in phase contrast (PC) congenital CMR flow measurements is caused by phase offsets due to local non-compensated eddy currents. Phantom correction of these phase offset errors has been shown to result in more accurate measurements of blood flow in adults with structurally normal hearts. We report the effect of phantom correction on PC flow measurements at...

متن کامل

Gender differences in response to cold pressor test assessed with velocity-encoded cardiovascular magnetic resonance of the coronary sinus

BACKGROUND Gender-specific differences in cardiovascular risk are well known, and current evidence supports an existing role of endothelium in these differences. The purpose of this study was to assess non invasively coronary endothelial function in male and female young volunteers by myocardial blood flow (MBF) measurement using coronary sinus (CS) flow quantification by velocity encoded cine ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2015