Differences in External and Internal Cortical Strain with Prosthesis in the Femur

نویسندگان

  • Olav Reikeras
  • Gudrun T Aarnes
  • Harald Steen
  • Per Ludvigsen
  • Geir Sagvolden
چکیده

The contact between a femoral stem prosthesis and the internal surface of the cortical bone with the stress in the interface is of crucial importance with respect to loosening. However, there are no reports of strain patterns at this site, and the main aim of the current study was to investigate differences of internal and external cortical strain in the proximal femur after insertion of a stem prosthesis. The external cortical strain of a human cadaveric femur was measured with strain gauges before and after implantation of a stem prosthesis. By use of optical fibres embedded longitudinally in the endosteal cortex, deformations at the implant-internal cortex interface could also be measured. The main external deformation during loading of the intact femur occurred as compression of the medial cortex; both at the proximal and distal levels. The direction of the principal strain on the medial and lateral aspects was close to the longitudinal axis of the bone. After resection of the femoral neck and insertion of a stem prosthesis, the changes in external strain values were greatest medially at the proximal level, where the magnitude of deformation in compression was reduced to about half the values measured on the intact specimen. Otherwise, there were rather small changes in external principal strain. However, by comparing vertical strain in the external and internal cortex of the proximal femur, there were great differences in values and patterns at all positions. The transcortical differences in strain varied from compression on one side to distraction on the other and vice versa in some of the positions with a correlation coefficient of 0.07. Our results show that differences exist between the external and internal cortical strain when loading a stem prosthesis. Hence, strain at the internal cortex does not correspond and can not be deducted from measured strain at the external cortex.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Case study of Performance Improvement of Femur Prosthesis

Nowadays, the placement of artificial prostheses in human skeleton, etc. is common due to different reasons such as fractures or deficiencies. Prostheses are structures that assist the performance of organs by reconstruction of some body parts through different methods to enable the organ to re-obtain its performance completely or partially and, since the use of external prostheses might lead t...

متن کامل

The effect of alendronate treatment on cortical thickness of the proximal femur in postmenopausal women

Background: Bisphosphonates (BPs) are used extensively for managing the osteoporosis. There are some controversies on atypical fractures of femur that associated with increase in cortical thickness (CT) and BPs’ use. In this study, the effects of alendronate consumption were studied on femoral CT as a predictor for atypical fracture.   Methods: Forty nine post-menopausal women age...

متن کامل

Effects of Strain, Age and the Interrelationships between External and Internal Qualities of Eggs in Two Strains of Layer Chickens in Northern Guinea Savannah Zone of Nigeria

An experiment was conducted to determine the differences in body weight (BW), feed intake (FI) and some egg production traits of two strains of layer chickens (Isa Brown and Nera Black) and correlate the relationships between the tested traits. The study commenced when the layers were 26 weeks old and a total of 200 (100 of each strain) were used. Sixty fresh eggs (30 from each strain) were col...

متن کامل

Tc-99m Labeled HMPAO white Blood Cell Scintigraphy in a patient with Hip Prosthesis

Background The ability to follow the distribution and migration of biologically active cells in human is essential for the development of cell-based therapies and diagnostics. Nuclear medicine imaging is widely applied in clinic as an attractive technique for in vivo WBC and stem cell tracking. The aim of this study was to evaluate prosthesis infection of a 51 years old man with previous histo...

متن کامل

Determination of Relationships between the Ultrasound Velocity and the Physical Properties of Bovine Cortical Bone Femur

Accurate measurements of physical characteristics of bone are essential for diagnosis, assessment of change following treatment, and therefore, indirectly, for evaluation of new forms of therapy. This is particularly true of osteoporosis and aging skeleton, in which fractures occur easily. Methods: In this study an ultrasonic system was set-up and calibrated on Plexiglas tubes of variable thick...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2011