Rat cardiopulmonary bypass model: application of a miniature extracorporeal circuit composed of asanguinous prime.
نویسندگان
چکیده
A clinically relevant rat cardiopulmonary bypass (CPB) model would be a valuable tool for investigating pathophysiological and therapeutic strategies on bypass. Previous rat CPB models have been described in the literature; however, they have many limitations, including large circuit surface area, the inability to achieve full bypass, and donor blood requirements for prime. Therefore, we have established a rat CPB model designed to overcome these limitations. The miniature circuit consisted of a filtered reservoir, heat exchanger, membrane oxygenator (surface area = 0.02 m2) with a static priming volume of 2.8 mL, and an inline blood gas monitor. The circuit was primed with 9.5+/-0.5 mL of crystalloid solution and CPB was established on male Sprague-Dawley rats (430-475 g, n = 5) by cannulating the left common carotid artery and the right external jugular vein. The animals were placed on CPB at full flow (111+/-13 mL/kg/ min) for 1 hour and were monitored for and additional 2 hours after the CPB procedure. Hemodynamics, hemoglobin concentration (Hb), and blood gases were analyzed at three time intervals: before, during, and after CPB. The circuit performance was evaluated according to prime volume, compliance, hemodynamic parameters, and gas and heat exchange as described by modified AMMI standards. Data are expressed as mean+/-SD and a repeated-measures analysis of variance with post-Hoc test was used for data comparison between the three time intervals. The ratio of oxygenator surface area to subject body weight for this model is comparable with that of current human adult CPB practice (0.05 m2/kg vs 0.057 m2/kg) Full CPB was achieved and we observed clinically acceptable PaO2, PaCO2, and SvO2 values (209+/-86 mmHg, 25+/-2 mmHg, 78+/-8%, respectively) while on CPB. The use of asanguinous prime did produce statistically significant Hg reduction (15.7+/-0.76 vs. 9.2+/-0.59 g/dL) comparable with clinical practice. No statistically significant differences between pre- and post-CPB hemodynamics and blood gases were found in our study. We have established a miniature circuit consisting of asanquineous prime for a rat CPB model that maintains clinically acceptable results regarding hemodynamic parameters, blood gases, and hemodilution. This model would be valuable for further use in clinically relevant research studies.
منابع مشابه
Experimental use of an ultra-low prime neonatal cardiopulmonary bypass circuit utilizing vacuum-assisted venous drainage.
In adult cardiopulmonary bypass surgery, vacuum assisted venous drainage has become a popular technique to augment venous return to the bypass circuit. The application of this technique in neonatal cardiopulmonary bypass surgery could be beneficial to the further miniaturization of neonatal circuitry by coupling radical respositioning of the oxygenator and pump console with decreasing line leng...
متن کاملAutologous priming technique to reduce blood transfusion in pediatric cardiopulmonary bypass.
Excessive hemodilution during cardiopulmonary bypass is associated with decreased oxygen carrying capacity, edema, and organ dysfunction. The use of blood products is often necessary to prime the extracorporeal circuit for pediatric cardiac surgical patients. However, the use of blood products carries serious risks both in the acute and long-term aspects of patient care. Autologous priming of t...
متن کاملHematological effects of a low-prime neonatal cardiopulmonary bypass circuit utilizing vacuum-assisted venous return in the porcine model.
Limiting hemodilution in neonates is difficult when extracorporeal circuits require priming volumes that are 2 to 3 times the blood volume of the newborn patient. This extreme hemodilution contributes to the development of significant postbypass coagulation disturbances. The purpose of this project was to design a low-prime neonatal bypass circuit and evaluate the coagulation status after reduc...
متن کاملChalk in the prime.
After observations of cloudiness in the perfusion circuit at open intracardiac operations, laboratory experiments showed a precipitate in a Hartmann's solution (compound sodium lactate solution, Ringer-lactate) and sodium bicarbonate based priming fluid used for cardiopulmonary bypass. The precipitate was found to consist of calcium carbonate crystals. The crystals were not dissolved by adding ...
متن کاملThe effectiveness of low-prime cardiopulmonary bypass circuits at removing gaseous emboli.
During extracorporeal circulation, the patient's blood is siphoned into the extracorporeal circuit (ECC) by gravity or may be assisted kinetically or by vacuum. In all instances, negative pressure is generated in the venous line, which can cause entrainment of air into the ECC at the cannulation site. The typical ECC uses a venous reservoir, membrane oxygenator, and arterial line filter, which ...