Exergy Analysis of a Dual-mode Refrigeration System for Ice Storage Air Conditioning

نویسندگان

  • Guiyin Fang
  • Lin Xing
  • Fan Yang
  • Hui Li
چکیده

This paper introduces the dual-mode refrigeration system for ice storage air conditioning. A computational model relating to the exergy loss amount and loss rate is developed in each component of the refrigeration cycle loop. A case study is presented to demonstrate the applicability of the model developed. Exergy analysis results of the refrigeration system in ice storage operating mode are compared with that of the refrigeration system in air conditioning operating mode. The results show that the exergy efficiency of the refrigeration system in ice storage operating mode is 17.63% lower than that of the refrigeration system in air conditioning operating mode. The energy saving and exergy loss reduction possibilities are also analyzed and discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Peak Shifting and Energy Saving Potential of Ice Storage Based Air Conditioning Systems in Iran

Thermal energy storage (TES) system has been introduced as a practical facility for shifting load from peak hours to off-peak hours. Because of different energy consumption during day and night, peak and off peak period is created on load curve. Ice storage technology which is a kind of TES system, is implemented in different points of the world with the purpose of solving load shifting problem...

متن کامل

Exergy Analysis of an Air Dehumidification System Equipped with Mixing Box and Heat Exchanger Heat Recovery Units

Exergy analysis emboldens in cases that all the inefficiencies and bottlenecks to improve energy systems are to be addressed. In this study, a novel vapor compression air dehumidifier integrated with an auxiliary heat exchanger in series arrangement with the main condenser in order to mitigate the reheat coil, and an extra mixing box to recover the ventilated air heat has been introduced. A com...

متن کامل

Theoretical Exergy Analysis of HFO-1234yf and HFO-1234ze as an Alternative Replacement of HFC-134a in Simple Vapour Compression Refrigeration System

An Exergy method for theoretical analysis of a traditional vapour-compression refrigeration system equipped with liquid vapour heat exchanger (lvhe) for HFO-1234yf (2, 3, 3, 3-Tetrafluoropropene) and HFO-1234ze (trans-1, 3, 3, 3-tetrafluoroprop-1-ene), both ultra low Global Warming Potential(GWP) and zero Ozone Depletion Potential(ODP) refrigerants and comparison of the results with HFC-134a re...

متن کامل

Saving Energy by Exergetic Analysis of MTP Process Refrigeration System

The exergetic analysis is a tool that has been used successfully in many studies aiming a more rational energy consumption to reduce the cost of processes. With this analysis, it is possible to perform an evaluation of the overall process, locating and quantifying the degradation of exergy. This paper applies exergy approach for analyzing the heat exchanger network design and refrigeration of M...

متن کامل

Advanced Exergy Evaluation of an Integrated Separation Process with Optimized Refrigeration System

Advanced exergy analysis is a tool to split the exergy destruction of the system to achieve a better perspective about the potentials of a system for improvements. In addition, the component interactions and their exergy destruction dependency with the other equipment are investigated through the advanced exergy analysis. For this purpose, it divides the exergy destruction calculated by convent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005