An Experimental Study of Compressibility Effects on the Film Cooling Effectiveness Using PSP and PIV Techniques
نویسندگان
چکیده
An experimental study was performed to examine effects of compressibility on film cooling effectiveness for coolant flowing from cylindrical holes in a flat plate. The incoming flow Mach number was set at 0.07, 0.30, 0.50 and 0.70. The Pressure Sensitive Paint (PSP) technique, which is based on a mass transfer analogy, was used to map the adiabatic film cooling effectiveness distribution on the surface of interest. The highresolution PSP measurement result showed that there was marginal enhancement of film cooling performance for higher Mach number flow comparing to the Ma=0.07 case. A high-resolution Particle Image Velocimetry (PIV) system was also used to conduct detailed flow field measurements to uncover the underlying physics of film cooling in the high speed flow, which showed similar flow field measurement results at M=0.4 for both Ma=0.07 and 0.30 cases, but slightly different ensemble-averaged velocity distribution was found for M=1.25 case.
منابع مشابه
An Experimental Study of Momentum-Preserving Shaped Holes for Film Cooling Using PSP and PIV
An experimental investigation was conducted to study the performance of film cooling injection from a cylindrical hole and a “W-shaped” hole. A Pressure Sensitive Paint (PSP) technique was used to map the spatial distribution of film cooling effectiveness on the surface of the test plate based on a mass-transfer analogy. The effects of mass flux ratio and density ratio on film cooling effective...
متن کاملAn experimental study of density ratio effects on the film cooling injection from discrete holes by using PIV and PSP techniques
Keywords: Film cooling of turbine blades Cooling effectiveness quantification Effects of coolant-to-mainstream density ratio PIV measurements PSP technique Mass transfer analog a b s t r a c t An experimental study was conducted to investigate the performance of film cooling injection from a row of circular holes spaced laterally across a flat test plate. While a high-resolution Particle Image ...
متن کاملAn Experimental Study of Film Cooling Effectiveness by Using PIV and PSP Techniques
An experimental study was conducted to investigate the performance of film cooling injection from a row of circular holes spaced laterally across a flat plate. A highresolution PIV system was used to conduct flow field measurements to reveal the tendencies of the coolant stream to remain attached to the test plate or to separate from it, and a Pressure Sensitive Paint (PSP) technique was used t...
متن کاملExperimental Investigation into the Hydrodynamics Effects of Slot Film Cooling on a Cylindrical Model
An experimental study of hydrodynamics of film cooling is performed by using a single longitudinal slot on a cylindrical model simulated to the leading edge of the gas turbine blade. The model is set up into the test section of an open-circuit induced flow wind tunnel which provides the main flow. The injected air, as a secondary film flow, produced from a high pressure compressor is considered...
متن کاملNumerical Simulation Of the Componend Angles Effects On Adiabatic Film Cooling Effectiveness
Abstract Film Cooling Adiabatic Effectiveness on a Profile of a Gas Turbine blade that Using Holes with 45 Degree Combined Angles to the Flow Direction and Radial Along the Attack Edge as well as 25 Degree Angles to the Flow Direction and Surface Area of the Attack Edge Area and 35 degrees relative to the outlet hole suefaces along stagnation line, Under a specified blowing ratios, using the Re...
متن کامل