Increased anterior temporal lobe T2 times in cases of hippocampal sclerosis: a multi-echo T2 relaxometry study at 3 T.

نویسندگان

  • Regula S Briellmann
  • Ari Syngeniotis
  • Steve Fleming
  • Renate M Kalnins
  • David F Abbott
  • Graeme D Jackson
چکیده

BACKGROUND AND PURPOSE Increased T2 relaxation times in the ipsilateral hippocampus are present in patients with hippocampal sclerosis. Visual assessment of T2-weighted images of these patients suggests increased signal intensity in the anterior temporal lobe as well. Our aim was to assess hippocampal and anterior temporal T2 relaxation times in patients with partial epilepsy by using a new T2-relaxometry sequence implemented by using a 3-T General Electric imaging unit. METHODS Coronal view T2 maps were generated by using an eight-echo Carr-Purcell-Meiboom-Gill sequence (TE, 28-231) with an acquisition time of 7 min on a 3-T General Electric Signa Horizon LX imaging unit. T2 relaxation times were measured in the hippocampus and anterior temporal lobe of 30 healthy control volunteers and 20 patients with partial epilepsy. RESULTS For the 30 control volunteers, the mean hippocampal T2 relaxation time was 98 +/- 2.8 ms. In all measured areas, the asymmetry index was small (<0.01). For the 15 patients with independent evidence of hippocampal sclerosis established by visual, volumetric, and, when available, pathologic criteria, mean hippocampal T2 relaxation times were 118 +/- 7 ms (P <.0001) on the ipsilateral side and 101 +/- 4 ms (P =.005) on the contralateral side. The T2 values were also increased in the anterior temporal lobe (ipsilateral: 82 +/- 6 ms, P <.0001; contralateral: 79 +/- 6 ms, P =.01) as compared with the values for the control volunteers (75 +/- 3 ms). The five patients with focal cortical dysplasia had hippocampal T2 relaxation times that were not different from control values. CONCLUSION T2 relaxometry at 3 T is feasible and useful and confirmed marked ipsilateral hippocampal signal intensity increase in patients with hippocampal sclerosis. Importantly, definite signal intensity change was also present in the anterior temporal lobe. T2 relaxometry is a sensitive means of identifying abnormalities in the hippocampus and other brain structures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated T2 relaxometry of the hippocampus for temporal lobe epilepsy

OBJECTIVE Hippocampal sclerosis (HS), the most common cause of refractory temporal lobe epilepsy, is associated with hippocampal volume loss and increased T2 signal. These can be identified on quantitative imaging with hippocampal volumetry and T2 relaxometry. Although hippocampal segmentation for volumetry has been automated, T2 relaxometry currently involves subjective and time-consuming manu...

متن کامل

Relative localizing value of amygdalo-hippocampal MR biometry in temporal lobe epilepsy.

OBJECTIVES The aims of the study were (i) to examine the localizing value of three MRI quantitative modalities (qMRI) currently used for the analysis of the hippocampus and amygdala in the context of pre-surgical screening and (ii) to propose a step-by-step protocol based on the sensitivity and performance of the different MR techniques. METHODS Ninety-two adults with chronic mesial temporal ...

متن کامل

T2 relaxometry of the hippocampus at 3T.

BACKGROUND AND PURPOSE T2 mapping is useful for identifying and quantifying abnormalities of the hippocampus and amygdala. It is particularly useful in the presurgical evaluation of patients with temporal lobe epilepsy and for the identification of bilateral hippocampal sclerosis (HS). The purpose of this study was to implement and validate a dual-echo method for producing coronal T2 maps with ...

متن کامل

Composite voxel-based analysis of volume and T2 relaxometry in temporal lobe epilepsy

Voxel-based analyses of tissue characteristics such as volume and T2 are usually carried out in isolation. However, as the images are analysed in a common voxel-based framework, it is possible to directly assess the spatial relationships of abnormalities detected by each technique. We utilize this approach in well-characterized patients with unilateral temporal lobe epilepsy (TLE) with hippocam...

متن کامل

Single subject voxel-based analysis in mesial temporal lobe epilepsy

Introduction: Voxel-based morphometry is a widely used clinical tool for detection of voxel-wise structural shape changes in subject groups using MRI. A related technique, voxel-based relaxometry (VBR), may be used to map changes in T2. Traditionally the techniques have been used to compare groups of subjects. In this context, the voxel-based techniques may not be used for the categorisation of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 25 3  شماره 

صفحات  -

تاریخ انتشار 2004