Quantification of orbital apex crowding for screening of dysthyroid optic neuropathy using multidetector CT.
نویسندگان
چکیده
BACKGROUND AND PURPOSE DON, a serious complication of GO, is frequently difficult to diagnose clinically in its early stages because of confounding signs and symptoms of congestive orbitopathy. We evaluated the ability of square area measurements of orbital apex crowding, calculated with MDCT, to detect DON. MATERIALS AND METHODS Fifty-six patients with GO were studied prospectively with complete neuro-ophthalmologic examination and MDCT scanning. Square measurements were taken from coronal sections 12 mm, 18 mm, and 24 mm from the interzygomatic line. The ratio between the extraocular muscle area and the orbital bone area was used as a CI. Intracranial fat prolapse through the superior orbital fissure was recorded as present or absent. Severity of optic nerve crowding was also subjectively graded on coronal images. Orbits were divided into 2 groups (with or without clinical evidence of DON) and compared. RESULTS Ninety-five orbits (36 with and 59 without DON) were studied. The CIs at all 3 levels and the subjective crowding score were significantly greater in orbits with DON (P < .001). No significant difference was observed regarding intracranial fat prolapse (P = .105). The area under the ROC curves was 0.91, 0.93, and 0.87 for CIs at 12, 18, and 24 mm, respectively. The best performance was at 18 mm, where a cutoff value of 57.5% corresponded to 91.7% sensitivity, 89.8% specificity, and an odds ratio of 97.2 for detecting DON. A significant correlation (P < .001) between the CIs and VF defects was observed. CONCLUSIONS Orbital CIs based on area measurements were found to predict DON more reliably than subjective grading of orbital crowding or intracranial fat prolapse.
منابع مشابه
Predicting dysthyroid optic neuropathy using computed tomography volumetric analyses of orbital structures
OBJECTIVE To evaluate the ability of orbital apex crowding volume measurements calculated with multidetector-computed tomography to detect dysthyroid optic neuropathy. METHODS Ninety-three patients with Graves' orbitopathy were studied prospectively. All of the patients underwent a complete neuro-ophthalmic examination and computed tomography scanning. Volumetric measurements were calculated ...
متن کاملDiagnostic Ability Of Barrett’s Index to Detect Dysthyroid Optic Neuropathy Using Multidetector Computed Tomography
OBJECTIVES The objective of this study was to evaluate the ability of a muscular index (Barrett's Index), calculated with multidetector computed tomography, to detect dysthyroid optic neuropathy in patients with Graves' orbitopathy. METHODS Thirty-six patients with Graves' orbitopathy were prospectively studied and submitted to neuro-ophthalmic evaluation and multidetector computed tomography...
متن کاملReversal of dysthyroid optic neuropathy following orbital fat decompression.
AIMS To document the successful treatment of five patients with dysthyroid optic neuropathy by orbital fat decompression instead of orbital bone decompression after failed medical therapy. METHODS Eight orbits of five patients with dysthyroid optic neuropathy were selected for orbital fat decompression as an alternative to bone removal decompression. Treatment with systemic corticosteroids an...
متن کاملOrbital Volumetry in Graves' Orbitopathy: Muscle and Fat Involvement in relation to Dysthyroid Optic Neuropathy
Purpose. We wanted to investigate the relative significance of fat and muscle enlargement in the development of dysthyroid optic neuropathy (DON) in Graves' orbitopathy (GO). Methods. Preoperative coronal CT scans of 13 patients with and without DON who subsequently underwent orbital decompression were retrospectively analyzed. Thirteen patients imaged for unilateral orbital fractures served as...
متن کاملClinical Profile and Visual Outcomes after Treatment in Patients with Dysthyroid Optic Neuropathy
PURPOSE To report the clinical data and visual outcomes after treatment of patients with dysthyroid optic neuropathy (DON). METHODS We retrospectively reviewed the medical records and orbital images of 40 patients (65 eyes) with DON and analyzed the visual outcomes after treatment with intravenous steroids pulse therapy, radiotherapy and orbital decompression. RESULTS The study included 21 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 33 8 شماره
صفحات -
تاریخ انتشار 2012