Detection of total and A1c-glycosylated hemoglobin in human whole blood using sandwich immunoassays on polydimethylsiloxane-based antibody microarrays.

نویسندگان

  • Huang-Han Chen
  • Chih-Hsing Wu
  • Mei-Ling Tsai
  • Yi-Jing Huang
  • Shu-Hui Chen
چکیده

The percentage of glycosylated hemoglobin A1c (%GHbA1c) in human whole blood indicates the average plasma glucose concentration over a prolonged period of time and is used to diagnose diabetes. However, detecting GHbA1c in the whole blood using immunoassays has limited detection sensitivity due to its low percentage in total hemoglobin (tHb) and interference from various glycan moieties in the sample. We have developed a sandwich immunoassay using an antibody microarray on a polydimethylsiloxane (PDMS) substrate modified with fluorinated compounds to detect tHb and glycosylated hemoglobin A1c (GHbA1c) in human whole blood without sample pretreatment. A polyclonal antibody against hemoglobin (Hb) immobilized on PDMS is used as a common capture probe to enrich all forms of Hb followed by detection via monoclonal anti-Hb and specific monoclonal anti-GHbA1c antibodies for tHb and GHbA1c detection, respectively. This method prevents the use of glycan binding molecules and dramatically reduces the background interference, yielding a detection limit of 3.58 ng/mL for tHb and 0.20 ng/mL for GHbA1c. The fluorinated modification on PDMS is superior to the glass substrate and eliminates the need for the blocking step which is required in commercial enzyme linked immunosorbent assay (ELISA) kits. Moreover, the detection sensitivity for GHbA1c is 4-5 orders of magnitude higher, but the required sample amount is 25 times less than the commercial method. On the basis of patient sample data, a good linear correlation between %GHbA1c values determined by our method and the certified high performance liquid chromatography (HPLC) standard method is shown with R(2) > 0.98, indicating the great promise of the developed method for clinical applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A lateral flow immunosensor for direct, sensitive, and highly selective detection of hemoglobin A1c in whole blood.

An immunosensor that operates based on the principles of lateral flow was developed for direct detection of hemoglobin A1c (HbA1c) in whole blood. We utilized colloidal gold-functionalized antibodies to transduce the specific signal generated when sandwich immuno-complexes were formed on the strip in the presence of HbA1c. The number and intensity of the test lines on the strips indicate normal...

متن کامل

Measurment of stable Glycosylated Hemoglobin (Hb A1) and Its unstable type (pre- Hb A1c) with the lon- exchange Chromatography in Diabetic patients

SUMMARY: At present, measurment of glycosylated hemoglobin, especially the stable fraction of hemoglobin (HbA1c) is one of the ways to control diabetes because this measurment can demonstrate total glycemia during last 1.2.3 months. Glycosylated hemoglobin is seen in 3 forms: Ala Alb A1c. Among these hemoglobin Alc is quantitively more than other 2 forms and its difference with other hemoglobi...

متن کامل

Diagnostic Value of Fructosamine and Glycosylated Hemoglobin in Estimating Blood Glucose Level in Diabetic Patients with Thalassemia Major

Abstract Background and Objective: Diabetes mellitus is one of complications that thalassemia major patients face with. Hence, blood glucose monitoring is of vital importance to these patients. Because of high level of fetal hemoglobin in these patients, the measurement of hemoglobin A1c is not reliable and should be displaced by fructosamine test. Material and Methods: The current descr...

متن کامل

Quantitative immunoassay of biotoxins on hydrogel-based protein microchips.

Three-dimensional gel-based microchips with immobilized proteins were used for quantitative immunoassay of a series of plant (ricin and viscumin) and bacterial (staphylococcal enterotoxin B, tetanus and diphtheria toxins, and lethal factor of anthrax) toxins. It was shown that different types of immunoassays (direct, competitive, and sandwich type) could be carried out on gel microchips. As sho...

متن کامل

Comparative study the effectiveness of Cognitive-Behavioral therapy and Compassion based therapy on sleep quality and glycosylated hemoglobin in diabetic patients

Introduction:Dabetes is one of the chronic medical problem with a varyrapid spread in the world.Diabetes is attracting more attention day by day to the late and dangerous complications and wildspread prevalence Method: The type of research was quasi -experimental with a pre-test-post-test design and follow-up with the control group. The statistical population included all patients with type 2 d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 84 20  شماره 

صفحات  -

تاریخ انتشار 2012