Diagnostic significance of flow separation within the carotid bifurcation demonstrated by digital subtraction angiography.
نویسندگان
چکیده
The presence of an area of reversed blood flow due to flow separation in the interval carotid artery is a normal finding in Doppler ultrasound studies in vivo as well as in model carotid bifurcations. This flow separation phenomenon is caused by the geometry of the carotid bifurcation and the fluid dynamics of blood. We demonstrated the flow separation phenomenon on lateral-projection intra-arterial digital subtraction angiograms in 99 of 100 carotid bifurcations. The mean duration of flow separation was 5.8 seconds, with values up to 14 seconds in normal carotid bifurcations. The presence of this flow separation phenomenon is almost independent of atherosclerotic lesions and is not correlated with cerebral ischemia. Therefore, the angiographic finding of a flow separation has no diagnostic value. However, our results refer to a factor that may be important in the genesis of atherosclerosis at the carotid bifurcation, namely the duration of the stay of blood and its components within the area of flow separation.
منابع مشابه
I.v. and intraarterial hybrid digital subtraction angiography: clinical evaluation.
Temporal/energy (hybrid) subtraction is a technique for removing soft-tissue motion artifact from digital subtraction angiograms. The diagnostic utility of hybrid subtraction for i.v. and intraarterial angiography was assessed in the first 9 months of operation of a dedicated production system. In i.v. carotid arteriography (N = 127), hybrid subtraction (H) provided a double-profile projection ...
متن کاملInraoperative and Histological Visualization of Disrupted Vulnerable Plaques following Diagnostic Angiography of Moderate Carotid Stenosis
Background. Digital subtraction angiography (DSA) remains an important tool for diagnosis of carotid stenosis but is associated with risk for periprocedural complications. This is the first report of direct intraoperative and histolopathologic visualization of DSA-related carotid plaque disruption. Case. A 64-year-old man diagnosed to have a 60% right carotid stenosis received diagnostic DSA fo...
متن کاملDynamic contrast-enhanced MR angiography and MR imaging of the carotid artery: high-resolution sequences in different acquisition planes.
BACKGROUND AND PURPOSE First-pass contrast-enhanced MR angiography has become the technique of choice for studying the carotid bifurcation, but this method has some limitations. We evaluated the clinical utility of performing 3D contrast-enhanced MR angiography in the axial plane immediately after performing angiography in the coronal plane. METHODS Cervical carotid arteries of 80 consecutive...
متن کاملCase Report Intractable Posterior Epistaxis due to a Spontaneous Low-Flow Carotid-Cavernous Sinus Fistula: A Case Report and a Review of the Literature
We report a case of a 90-year-old patient with intractable posterior epistaxis presenting as the only symptom of a nontraumatic low-flow carotid-cavernous sinus fistula. Purpose of this case report is to introduce low-flow carotid-cavernous sinus fistula in the differential diagnosis of intractable posterior epistaxis. We provide a literature review for the sequence of actions for the confronta...
متن کاملThe role of venous digital subtraction angiography of the carotid bifurcation in the evaluation of patients with reversible ischemic attacks or stroke.
The diagnostic value of venous digital subtraction angiography (VDSA) was evaluated in 168 consecutive patients with suspected or known atherosclerotic lesions of the internal carotid artery. The VDSA findings were correlated with that of arterial angiography (AA) in 50 patients, yielding a sensitivity of 84%, a specificity of 93% and an accuracy of 89%. Correlation of the results of Doppler wi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Stroke
دوره 21 12 شماره
صفحات -
تاریخ انتشار 1990