Relationship to the ideal transformer
نویسنده
چکیده
A gyrator is a passive, linear, lossless, two-port electrical network element proposed in 1948 by Bernard D. H. Tellegen as a hypothetical fifth linear element after the resistor, capacitor, inductor and ideal transformer. Unlike the four conventional elements, the gyrator is non-reciprocal. Gyrators permit network realizations of two-(or-more)-port devices which cannot be realized with just the conventional four elements. In particular, gyrators make possible network realizations of isolators and circulators. Gyrators do not however change the range of one-port devices that can be realized. Although the gyrator was conceived as a fifth linear element, its adoption makes both the ideal transformer and either the capacitor or inductor redundant. Thus the number of necessary linear elements is in fact reduced to three. Circuits that function as gyrators can be built with transistors and op amps using feedback.
منابع مشابه
Kalman-Filter Based Estimation of Electric Load Composition with Non-ideal Transformer Modeling
This paper presents a study to estimate the composition of an electric load, i.e. to determine the amount of each load class by the direct measurements of the total electric current waveform from instrument reading. Kalman filter algorithm is applied to estimate the electric load composition on a consumer side of a distributed power system. The electric load supplied from the different voltage ...
متن کاملMathematical Proof for the Minimized Stray Fields in Transformers Using Auxiliary Windings Based on State Equations for Evaluation of FEM Results
Stray magnetic field is one of the main issues in design of transformers, since it causes non-ideal behavior of transformers. One of the techniques is usually adopted to mitigate the unwanted stray magnetic field is the use of auxiliary windings creating a magnetic field opposite to the incident one giving rise to the reduction of the total magnetic fields. This paper presents a new mathematica...
متن کاملDetermination of a new model to study ultra-saturation phenomenon during the loaded power transformer energization and its effect on differential protection
One of transient phenomenon that causes the mal-operation of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. In this paper, a new model for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the pow...
متن کاملSimulation and Analytical Investigation of Different Combination of Single Phase Power Transformers
Abstract—In this paper, the equivalent circuit of the ideal singlephase power transformer with its appropriate voltage current measurement was presented. The calculated values of the voltages and currents of the different connections single phase normal transformer and the results of the simulation process are compared. As it can be seen, the calculated results are the same as the simulated res...
متن کاملUPFC Ideal Transformer Model
This paper presents a unified power flow controller (UPFC) model, which consists of an ideal transformer with a complex turns ratio and a variable shunt admittance. In this model, the UPFC control variables do not depend explicitly on UPFC input and output currents and voltages. Accordingly, this model does not require adding extra busses for UPFC input and output. This model is easily combined...