A Gas Pressure Scale Based on Primary Standard Piston Gauges

نویسندگان

  • Douglas A. Olson
  • R. Greg Driver
  • Walter J. Bowers
چکیده

The National Institute of Standards and Technology (NIST) has redefined its gas pressure scale, up to 17 MPa, based on two primary standard piston gauges. The primary standard piston gauges are 35.8 mm in diameter and operate from 20 kPa to 1 MPa. Ten secondary standard piston gauges, two each of five series of the Ruska 2465 type, with successively smaller diameters form the scale extending up to 17 MPa. Six of the piston gauges were directly compared to the primary standards to determine their effective area and expanded (k = 2) uncertainty. Two piston gauges operating to 7 MPa were compared to the 1.4 MPa gauges, and two piston gauges operating to 17 MPa were compared to the 7 MPa gauges. Distortion in the 7 MPa piston gauges was determined by comparing those gauges to a DH Instruments PG7601 type piston gauge, whose distortion was calculated using elasticity theory. The relative standard uncertainties achieved by the primary standards range from 3.0 × 10(-6) to 3.2 × 10(-6). The relative standard uncertainty of the secondary standards is as low as 4.2 × 10(-6) at 300 kPa. The effective areas and uncertainties were validated by comparison to standards of other National Metrology Institutes (NMIs). Results show agreement in all cases to better than the expanded (k = 2) uncertainty of the difference between NIST and the other NMIs, and in most cases to better than the standard (k = 1) uncertainty of the difference.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of a compact 200 MPa controlled clearance piston gauge as a primary pressure standard using the Heydemann and Welch method

Controlled clearance piston gauges are used as primary pressure standards at many national metrology institutes. The National Institute of Standards and Technology, in collaboration with the National Physical Laboratory (India), is studying the performance of a new generation of controlled clearance gauges that offer the potential for reduced uncertainties. The gauges are also well suited to in...

متن کامل

A capacitive probe for measuring the clearance between the piston and the cylinder of a gas piston gauge.

We used a capacitive technique to determine the radial clearance between the piston and cylinder of a gas piston gauge. This method determines the effective area of a piston gauge pressure standard, independent of calibration against another piston gauge or manometer, as long as the diameter of the piston is dimensionally measured. It also allows an independent determination of piston gauge dis...

متن کامل

An Investigation on the Effects of Gas Pressure Drop in Heat Exchangers on Dynamics of a Free Piston Stirling Engine

This paper is devoted to study the effects of pressure drop in heat exchangers on the dynamics of a free piston Stirling engine. First, the dynamic equations governing the pistons as well as the gas pressure equations for hot and cold spaces of the engine are extracted. Then, by substituting the obtained pressure equations into the dynamic relationships the final nonlinear dynamic equations gov...

متن کامل

A Method of Traceability for a Fpg8601 Force Balanced Piston Gauge to Define Pressures in the Range from 1 Pa to 15 Kpa in Gauge and Absolute Measurement Modes

 The FPG8601 has become an important reference for many primary measurement laboratories in a pressure range from approximately 1 Pa to 15 kPa in both gauge and absolute measurement modes. The FPG8601 measurement range spans the gap between the traditional measurement regimes of ‘pressure’ and ‘vacuum’, a range where other primary pressure standards either do not exist or do not have uncertain...

متن کامل

Accurate characteristics of Helium in nano-channels

This article describes an accurate subPico flowmeter bifurcatedin to liquid and gas flowrates less than 1mol/s for both MEMS/NEMS and cryogenic technology applications. The MEMS/NEMS are described as either two Gauges (instrument), or quartz fluctuating forks, even if the liquid or gas flows through an element, as well as cryogenic technology consisting of arrays of e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 115  شماره 

صفحات  -

تاریخ انتشار 2010