Dielectric dispersion in aqueous solutions of oxyhaemoglobin and carboxyhaemoglobin.

نویسندگان

  • E H Grant
  • G P South
  • S Takashima
  • H Ichimura
چکیده

The relative permittivity and conductivity of aqueous solutions of oxyhaemoglobin and carboxyhaemoglobin were measured over the frequency range 150kHz-100MHz. To minimize errors of measurement the investigations were carried out with three different samples of each type of haemoglobin, independent apparatus being used in two different laboratories. The dielectric increment and relaxation time were calculated at each of several temperatures from the results. These lead to a dipole moment of 400 Debyes and an activation enthalpy of 17.6+/-1.4kJ.mol(-1), both of which were found to be independent of temperature to within experimental error over the range 3-35 degrees C. The value of the dipole moment shows that the distribution of charge throughout the haemoglobin molecule is nearly symmetrical with respect to the centre of charge. The magnitude of the activation enthalpy is similar to that of the viscosity of water, in accord with the common observation that dielectric relaxation and viscosity are related phenomena. No significant differences are found between the dielectric parameters of oxyhaemoglobin and carboxyhaemoglobin. Combining the results with those obtained from X-ray diffraction of the solid a hydration value of 0.45g of water/g of protein is suggested, subject to the limitations of the model used. Finally, the results indicate the presence of a subsidiary dispersion, which could be attributed to the above quantity of bound water having a static permittivity of about 100 and a relaxation frequency in the region 100-200MHz.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Sensitive Method for the Determination of Carboxyhaemoglobin in a Finger Prick Sample of Blood.

About 0-01 ml. of blood taken from a finger prick is dissolved in 10 ml. of 0-04% ammonia solution. The solution is divided into two halves, and oxygen is bubbled through one half to convert any carboxyhaemoglobin into oxyhaemoglobin. The spectra of the two halves are then compared in a spectrophotometer, and the difference between them is used to estimate the carboxyhaemoglobin content of the ...

متن کامل

Carboxyhaemoglobin: a possible reference material for haemoglobin assay.

The inter- and intralaboratory quality control of haemoglobin estimation in remote laboratories requires a more rugged control haemolysate than is commercially available. The stabilities of oxyhaemoglobin and carboxyhaemoglobin forms of an ethanediol-containing haemolysate were studied over a three-year period. From the results obtained, carboxyhaemoglobin under nitrogen is proposed as a possib...

متن کامل

Dielectric Dispersion Study of Aqueous Solutions

A dielectric measurement for the aqueous solutions at lower frequencies (20Hz to 2MHz) has been carried out in frequency domain using Agilient Precision LCR meter (E4980A). The dielectric permittivity spectra of over entire concentrations with aqueous solutions are measured at 25 ̊C. From observed spectra, static dielectric constants (ε0) have been determined. Dielectric Spectroscopy is especial...

متن کامل

Polarization-Sensitive Resonance CSRS of Deoxy- and Oxyhaemoglobin

Polarization-semitive coherent Stokes Raman scattering (CSRS) measurements of oxyand deoxyhaemoglobin in aqueous solutions are reported. The excitation wavelengths used were chosen in the region of the Q absorption bands to achieve twofold electronic resonance. The dispersion profiles of all independent susceptibility x(3 ) components and purely anisotropic and anti-symmetric scattering contrib...

متن کامل

Determination of the carboxyhaemoglobin saturation of blood by spectrophotometric analysis.

The spectrophotometric method of Commins and Lawther (I965) for the determination of carboxy-haemoglobin saturation in blood was found to lead to systematic undervaluation, because of dissociation of the carboxyhaemoglobin, and physical dissolution of the carbon monoxide in the solvent used for the analysis. The theoretical relationship between the true and apparent carboxyhaemoglobin saturatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Biochemical journal

دوره 122 5  شماره 

صفحات  -

تاریخ انتشار 1971