Guide Catheter Extension Device Is Effective in Renal Angioplasty for Severely Calcified Lesions
نویسندگان
چکیده
BACKGROUND The GuideLiner catheter extension device is a monorail-type "Child" support catheter that facilitates coaxial alignment with the guide catheter and provides an appropriate back-up force. This device has been developed in the field of coronary intervention, and now is becoming widely applied in the field of endovascular treatment. However, there has been no report on the effectiveness of the guide catheter extension device in percutaneous transluminal renal angioplasty (PTRA). CASE REPORT We encountered a case of atherosclerotic subtotal occlusion at the ostium of the left renal artery. Due to the severely calcified orifice and weaker back-up force provided by a JR4 guide catheter, we could not pass any guidewires through the target lesion. Therefore, we introduced a guide catheter extension device, the GuideLiner catheter, through the guide catheter and achieved good guidewire maneuverability. We finally deployed 2 balloon-expandable stents and successfully performed all PTRA procedures. CONCLUSIONS The guide catheter extension device can be effective in PTRA for severely calcified subtotal occlusion.
منابع مشابه
Complex Coronary Interventions with the Novel Mozec™ CTO Balloon: The MOZART Registry
BACKGROUND Mozec™ CTO is a novel semicompliant rapid-exchange PTCA balloon catheter with specific features dedicated to treat complex coronary lesions like chronic total occlusions (CTOs). However, no data have been reported about the performance of this device in an all-comers population with complex coronary lesions. METHODS We evaluated the safety and success rate of Mozec™ CTO balloon in ...
متن کاملIndependent predictors of restenosis after percutaneous coronary revascularization in haemodialysis patients.
BACKGROUND Percutaneous balloon angioplasty has become a well-established and routine procedure for coronary revascularization of haemodialysis patients with coronary artery disease. However, the incidence of restenosis after balloon angioplasty is significantly higher in haemodialysis patients than in the general population. We performed a retrospective study comparing balloon angioplasty with...
متن کاملInstent restenosis after carotid stenting: treatment using an off-label cardiac scoring balloon.
BACKGROUND Treatment of instent restenosis after carotid artery stenting because of circumferential or calcified lesions can be difficult and refractory to conventional balloon angioplasty. We describe the off-label use of a cardiac scoring balloon that was used for lesions refractory to angioplasty with other balloons. CASE DESCRIPTIONS Two patients with a history of carotid artery stenting ...
متن کاملRotational atherectomy ablation for an unexpandable stent under the guide of IVUS
RATIONALE Inadequate stent expansion due to rigid calcified may result in restenosis lesions, but the available options are limited. PATIENT CONCERNS We report a case via the trans-radial approach of the severely underexpanded freshly deployed stent due to heavily calcified plaques DIAGNOSES:: Coronary angiography revealed that there was no adequate expansion of the freshly deployed stent. ...
متن کاملUsefulness and Safety of a Guide Catheter Extension System for the Percutaneous Treatment of Complex Coronary Lesions by a Transradial Approach
OBJECTIVE The aim of this study was to describe our initial experience with the GuideLiner® catheter (Vascular Solutions Inc.) in the transradial treatment of complex lesions. MATERIALS AND METHODS The clinical, angiographic and procedural data of percutaneous coronary interventions where GuideLiner was used during 2013 were collected. The transradial approach was used in all cases. The indic...
متن کامل