Anatomical and functional intrapulmonary shunt in acute respiratory distress syndrome.
نویسندگان
چکیده
OBJECTIVES The lung-protective strategy employs positive end-expiratory pressure to keep open otherwise collapsed lung regions (anatomical recruitment). Improvement in venous admixture with positive end-expiratory pressure indicates functional recruitment to better gas exchange, which is not necessarily related to anatomical recruitment, because of possible global/regional perfusion modifications. Therefore, we aimed to assess the value of venous admixture (functional shunt) in estimating the fraction of nonaerated lung tissue (anatomical shunt compartment) and to describe their relationship. DESIGN Retrospective analysis of a previously published study. SETTING Intensive care units of four university hospitals. PATIENTS Fifty-nine patients with acute lung injury/acute respiratory distress syndrome. INTERVENTIONS Positive end-expiratory pressure trial at 5 and 15 cm H2O positive end-expiratory pressures. MEASUREMENTS AND MAIN RESULTS Anatomical shunt compartment (whole-lung computed tomography scan) and functional shunt (blood gas analysis) were assessed at 5 and 15 cm H2O positive end-expiratory pressures. Apparent perfusion ratio (perfusion per gram of nonaerated tissue/perfusion per gram of total lung tissue) was defined as the ratio of functional shunt to anatomical shunt compartment. Functional shunt was poorly correlated to the anatomical shunt compartment (r2 = .174). The apparent perfusion ratio at 5 cm H2O positive end-expiratory pressure was widely distributed and averaged 1.25 +/- 0.80. The apparent perfusion ratios at 5 and 15 cm H2O positive end-expiratory pressures were highly correlated, with a slope close to identity (y = 1.10.x -0.03, r2 = .759), suggesting unchanged blood flow distribution toward the nonaerated lung tissue, when increasing positive end-expiratory pressure. CONCLUSIONS Functional shunt poorly estimates the anatomical shunt compartment, due to the large variability in apparent perfusion ratio. Changes in anatomical shunt compartment with increasing positive end-expiratory pressure, in each individual patient, may be estimated from changes in functional shunt, only if the anatomical-functional shunt relationship at 5 cm H2O positive end-expiratory pressure is known.
منابع مشابه
Effects of acute hemorrhage on intrapulmonary shunt in a pig model of acute respiratory distress-like syndrome.
BACKGROUND In acute respiratory distress syndrome (ARDS), gas exchange and respiratory system mechanics (compliance) are severely impaired. Besides ventilatory parameters, the degree of respiratory abnormality can be influenced by the circulatory state. This study investigated the influence of acute hypovolemia on the respiratory system. METHODS We performed a secondary analysis of a previous...
متن کاملAcute Respiratory Distress Syndrome
ACCP Critical Care Board Review 2003 T acute respiratory distress syndrome (ARDS) and the related acute lung injury (ALI) syndromes are forms of Type I or acute hypoxemic respiratory failure (AHRF). This form of lung dysfunction rises from diseases causing collapse and/or filling of alveoli with the result that a substantial fraction of mixed venous blood traverses nonventilated airspaces, effe...
متن کاملNon-invasive measurement of pulmonary blood flow during prone positioning in patients with early acute respiratory distress syndrome.
In the daily clinical routine at the bedside, information on effective pulmonary blood flow (PBF) is limited and requires invasive monitoring, including a pulmonary artery catheter, to determine both cardiac output and intrapulmonary shunt. Therefore we evaluated a non-invasive method for the measurement of PBF in a clinical setting, including 12 patients with acute respiratory failure (acute r...
متن کاملValidity of Spo2/Fio2 Ratio in Detection of Acute Lung Injury and Acute Respiratory Distress Syndrome
Introduction: One ofdiagnostic criteria for Acute Lung Injury and Acute Respiratory Distress Syndrome is pao2/fio2 (PF) ratio 300 for ALI or 200 for ARDS. This criteria requires invasive arterial sampling. Measurement of Spo2/Fio2 (SF) ratio by pulseoximetry may be a reliable non invasive alternative to the PF ratio. Methods and Materials: In a cross sectional study we enrolled 105 sample o...
متن کاملRhabdomyolysis and Acute Respiratory Distress Syndrome Secondary to Multiple Wasp Stings
Background: Wasp stings usually cause local reactions such as itching, urticaria, angioedema and anaphylaxis. Life-threatening complications following multiple wasp stings are relatively rare and unexpected. However, rhabdomyolysis and acute respiratory distress syndrome following wasp stings are possible. Case presentation: A middle-aged male worker was stung by a swarm of wasps all over his b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Critical care medicine
دوره 36 3 شماره
صفحات -
تاریخ انتشار 2008