MRI-compatible micromanipulator: Positioning repeatability tests & kinematic calibration.
نویسندگان
چکیده
In this paper, we report results from positioning repeatability tests and kinematic calibration of our magnetic resonance imaging (MRI)-compatible micromanipulator. This manipulator provides medical and biological scientists with the ability to concurrently manipulate and observe micrometer size objects inside an MRI-gantry. We have already reported on its design, implementation, and the results of preliminary testing of MRI compatibility. Here we test positioning repeatability, which is essential for micromanipulation. The results show that the manipulator has high repeatability (0.7 microm in longitude and 3.0 microm in latitude). In addition, we performed a calibration of kinematics and discussed the experimental result in comparison with the theoretical model. The results show that its workspace is 50-70% smaller than theoretically expected. The results also show that the absolute positioning errors are 16, 9, 5 microm in x, y, and z directions, respectively.
منابع مشابه
Precise Evaluation of Positioning Repeatability of MR-Compatible Manipulator Inside MRI
In this paper, we experimentally tested the positioning repeatability of MR-compatible manipulator with a CCD laser micrometer inside MRI. To evaluate the performance of MR-compatible manipulator inside MRI, the measuring system must be confirmed to work correctly inside MRI in advance. Therefore, the measuring system was tested to see if it can measure a specimen similarly regardless to inside...
متن کاملFull parameter calibration of parallel mechanism
Calibration of a parallel mechanism using a specified artifact, artifact calibration, is an effective method. However, there are strong correlations between each parameter in an artifact calibration of a parallel mechanism. Therefore, it is difficult to identify all kinematic parameters included in a kinematic model of the parallel mechanism from measuring data. In this research, we propose two...
متن کاملCalibration of an Industrial Robot using a Stereo Vision System
Industrial robots have very good repeatability but still lack good absolute accuracy. The main reason is difference between the ideal robot kinematic model integrated in the robot controller and actual robot parameters. A method for identifying certain parameters of the robot model has been proposed. A noncontact method using a stereovision system attached to the robot arm is utilized for provi...
متن کاملPosition Control of a Compliant Mechanism Based Micromanipulator
Abstracz This paper addresses the modeling and control of a compliant micromanipulator for use in such$elh as microsurgery, telesurgery, and microassembly, The unique flexure-based manipulator utilizes revolute flexure joints in achieving well-behaved kinematic characteristics, without the backlash and stick-slip phenomena that would otherwise impede precision control. A mathematical model of t...
متن کاملMillimeter Scale Microrobots for the Nanoassembly Applications
Current top down manipulation systems used in micro and nanomanufacturing are many orders of magnitude larger than the parts being handled, leading to difficult tradeoffs between their precision, throughput and cost. This paper presents recent research progress in the manufacturing of millimeter sized robotic positioning technology that allows combining high precision with high throughput along...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference
دوره 2009 شماره
صفحات -
تاریخ انتشار 2009