Saturated LMI Control of Hysteretic Base-Isolated Structures
نویسندگان
چکیده
The main objective of applying active control forces to base-isolated structures is to protect them in the event of an earthquake. An LMI-based control design is proposed to attenuate seismic disturbances in base-isolated structures under saturation actuators. Using a simplified model of the structure system, a control algorithm design is offered. Performance evaluation of the controller is carried out in a simplified model version of a benchmark building system, which is recognized as a state-of-the-art model for numerical experiments of structures under seismic perturbations. Experimental results show that the proposed algorithm is robust with respect to model and seismic perturbations. Finally, the performance indices show that the proposed controller behaves satisfactorily and with a reasonable control effort. Copyright c ©2008 IFAC
منابع مشابه
Robust control of hysteretic base-isolated structures under seismic disturbances
The main objective of applying robust active control to base-isolated structures is to protect them in the event of an earthquake. Taking advantage of discontinuous control theory, a static discontinuous active control is developed using as a feedback only the measure of the velocity at the base. Moreover, due to that in many engineering applications, accelerometers are the only devices that pr...
متن کاملVibration Attenuation of Nonlinear Hysteretic Structures with Fully Unknown Parameters
Natural hazards such as earthquakes have threatened the life of human beings during the history.As a consequence, the vibration mitigation of structures has caught great importance. Activecontrol of structures is one of the rapidly emerging areas in the concept of structural control. Thispaper presents a control method to deal with this subject when the dynamics of the structure ishysteretic an...
متن کاملEvaluation of the SEAOC/UBC97 Provisions for the Tall Base-Isolated Structures
The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...
متن کاملEvaluation of the SEAOC/UBC97 Provisions for the Tall Base-Isolated Structures
The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...
متن کاملEvaluation of Damage Distribution in Elements of Dual Frames
Researches show that the strength criterion is inadequate for design of structures against seismic loads. Since structures yield and experience plastic deformation under strong ground motion, considering structural damage with inelastic behavior may be a considerable criterion for design and control of the structures.In this paper, three steel structures with dual system consisting of intermedi...
متن کامل