An injection and mixing element for delivery and monitoring of inhaled nitric oxide

نویسندگان

  • Andrew R. Martin
  • Chris Jackson
  • Samuel Fromont
  • Chloe Pont
  • Ira M. Katz
  • Georges Caillobotte
چکیده

BACKGROUND Inhaled nitric oxide (NO) is a selective pulmonary vasodilator used primarily in the critical care setting for patients concurrently supported by invasive or noninvasive positive pressure ventilation. NO delivery devices interface with ventilator breathing circuits to inject NO in proportion with the flow of air/oxygen through the circuit, in order to maintain a constant, target concentration of inhaled NO. METHODS In the present article, a NO injection and mixing element is presented. The device borrows from the design of static elements to promote rapid mixing of injected NO-containing gas with breathing circuit gases. Bench experiments are reported to demonstrate the improved mixing afforded by the injection and mixing element, as compared with conventional breathing circuit adapters, for NO injection into breathing circuits. Computational fluid dynamics simulations are also presented to illustrate mixing patterns and nitrogen dioxide production within the element. RESULTS Over the range of air flow rates and target NO concentrations investigated, mixing length, defined as the downstream distance required for NO concentration to reach within ±5 % of the target concentration, was as high as 47 cm for the conventional breathing circuit adapters, but did not exceed 7.8 cm for the injection and mixing element. CONCLUSION The injection and mixing element has potential to improve ease of use, compatibility and safety of inhaled NO administration with mechanical ventilators and gas delivery devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nitric oxide administration using constant-flow ventilation.

Nitric oxide (NO) gas is known as both a vasodilator and a toxin. It can react with oxygen to form compounds more toxic than itself, such as nitrogen dioxide (NO2). The reactions are time dependent; thus, infusing NO into breathing circuits as close to ventilated subjects as possible may help minimize toxic byproduct exposure. Unfortunately, flow rates commonly used with mechanical ventilation ...

متن کامل

Monitoring of Serum Nitric oxide in Patients with Acute Leukemia

Nitric oxide (NO) is a molecule required for many physiological functions, produced from L-arginine by NO synthases (NOS). It is a free radical, producing many reactive intermediates that account for its bioactivity. Sustained induction of the inducible form of NOS (iNOS) in chronic inflammation may be mutagenic, through NO-mediated DNA damage or hindrance to DNA repair, and thus potentially ca...

متن کامل

Monitoring of Serum Nitric oxide in Patients with Acute Leukemia

Nitric oxide (NO) is a molecule required for many physiological functions, produced from L-arginine by NO synthases (NOS). It is a free radical, producing many reactive intermediates that account for its bioactivity. Sustained induction of the inducible form of NOS (iNOS) in chronic inflammation may be mutagenic, through NO-mediated DNA damage or hindrance to DNA repair, and thus potentially ca...

متن کامل

Formation of nitrogen dioxide from nitric oxide and their measurement in clinically relevant circumstances.

Therapy with inhaled nitric oxide in oxygen requires adequate monitoring of nitric oxide and nitrogen dioxide. The characteristics of chemiluminescence and electrochemical measurement techniques were determined by analysis of continuously flowing gas mixtures and comparisons with traceable gas standards. Gas mixtures were also diluted with mass flow controllers and in addition created in ventil...

متن کامل

Performance of proportional and continuous nitric oxide delivery systems during pressure- and volume-controlled ventilation.

We have evaluated the effect of delivering nitric oxide using a continuous flow system (CFS) or two commercially available proportional gas injection systems (PGIS), Nodomo (Dräger, Lübeck, Germany) and Pulmonox-Mini (Messer Griesheim Austria, Gumpoldskirchen, Austria) on measured and simulated concentrations of nitric oxide. Nitric oxide concentration was measured in a bench test at five sites...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2016