Root proximity and stability of orthodontic anchor screws.
نویسنده
چکیده
This study aimed to investigate a causal relationship between the stability of orthodontic anchor screws (screws) and the degree of their proximity to the root (root proximity) using mobility test device (Periotest) and cone-beam computed tomography (CBCT). In total, 165 (diameter 1.6 mm; length 8 mm) screws in 58 patients (average age, 24.4 ± 8.5 years) were evaluated. After screw placement, CBCT was used for diagnostic imaging of the area around the site. Root proximity was evaluated and categorized into three groups: A, no contact; B, single contact; and C, multi-contact. The Periotest value was used to assess screw stability. The screw failure rate according to root proximity significantly differed between categories A and C. In addition, failure rate significantly differed between mandibular screws with and without root contact. Periotest values in categories A and C were significantly higher in the mandible than in the maxilla. Mandibular screws had greater mobility than maxillar screws, even when the screw avoided root contact. The lower stability of mandibular screws with root contact might be related to their greater mobility.
منابع مشابه
Thread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis
Orthodontic miniscrews are widely used as temporary anchorage devices to facilitate orthodontic movements. Miniscrew loosening is a common problem, which usually occurs during the first two weeks of treatment. Macrodesign can affect the stability of a miniscrew by changing its diameter, length, thread pitch, thread shape, tapering angle and so on. In this study, a 3-D finite element analysis wa...
متن کاملThe effect of insertion angle on orthodontic mini-screw torque
BACKGROUND Primary stability is an important factor for the clinical success of orthodontic mini-screws. The present study made an attempt to evaluate the effect of insertion angle changes on the maximum insertion and removal torque of orthodontic mini-screws. MATERIALS AND METHODS In this experimental study, 72 mini-screws (Dual Top Anchor System, Jeil, 1.6 mm diameter, 8 mm length) were use...
متن کاملOrthodontic and Orthognathic Surgical Treatment of Severe Skeletal Class III with the Use of Resorbable Plates and Screws: A Case Report
This paper presents a case of a female patient with severe skeletal Class III due to pronounced mandibular macrognathia combined with maxillary hypoplasia. The patient was treated with 2-jaw osteotomy in conjunction with preand post-operative orthodontic treatment. Resorbable surgical plates and screws were used for the orthognathic surgery to avoid potential complications from the use of metal...
متن کاملSurgical Intervention for Instability of the Craniovertebral Junction
Surgical approaches for stabilizing the craniovertebral junction (CVJ) are classified as either anterior or posterior approaches. Among the anterior approaches, the established method is anterior odontoid screw fixation. Posterior approaches are classified as either atlanto-axial fixation or occipito-cervical (O-C) fixation. Spinal instrumentation using anchor screws and rods has become a popul...
متن کاملEvaluation of primary stability of innovated orthodontic miniscrew system (STS): An ex-vivo study
BACKGROUND Stability is determined as one of the requirements in use of Temporary Anchorage Devices (TAD) in orthodontics. Miniscrew has been a widely used Bone Anchor. Compared with mini-implant that necessitates osseointegration; mechanical retention is a determining factor for primary stability of miniscrew. Studies investigated various ways to increase primary stability. The aim of this stu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of oral science
دوره 56 1 شماره
صفحات -
تاریخ انتشار 2014