Malrotation causing patellofemoral complications after total knee arthroplasty.

نویسندگان

  • R A Berger
  • L S Crossett
  • J J Jacobs
  • H E Rubash
چکیده

Thirty patients with isolated patellofemoral complications after total knee arthroplasty were compared with 20 patients with well functioning total knee replacements without patellofemoral complications. The epicondylar axis and tibial tubercle were used as references on computed tomography scans to measure quantitatively rotational alignment of the femoral and tibial components. The group with patellofemoral complications had excessive combined (tibial plus femoral) internal component rotation. This excessive combined internal rotation was directly proportional to the severity of the patellofemoral complication. Small amounts of combined internal rotation (1 degree-4 degrees) correlated with lateral tracking and patellar tilting. Moderate combined internal rotation (3 degrees-8 degrees) correlated with patellar subluxation. Large amounts of combined internal rotational (7 degrees-17 degrees) correlated with early patellar dislocation or late patellar prosthesis failure. The control group was in combined external rotation (10 degrees-0 degree). The direct correlation of combined (femoral and tibial) internal component rotation to the severity of the patellofemoral complication suggests that internal component rotation may be the predominant cause of patellofemoral complications in patients with normal axial alignment. The epicondylar axis and tibial tubercle are reproducible landmarks which are visible on computed tomography scans and can be used intraoperatively. Using this computed tomography study can determine wether rotational malalignment is present and thus, whether revision of one or both components may be indicated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of malrotation of the femoral component in total knee replacement on the mechanics of patellofemoral contact during gait: an in vitro biomechanical study.

Malrotation of the femoral component is a cause of patellofemoral maltracking after total knee arthroplasty. Its precise effect on the patellofemoral mechanics has not been well quantified. We have developed an in vitro method to measure the influence of patellar maltracking on contact. Maltracking was induced by progressively rotating the femoral component either internally or externally. The ...

متن کامل

The effect of femoral component rotation on the extensor retinaculum of the knee.

Malrotation of the femoral component may cause patellofemoral complications after total knee replacement (TKR). We hypothesized that femoral component malrotation would cause excessive lengthening of the retinacula. Retinacular length changes were measured by threading fine sutures along them and attaching these to the patella and to displacement transducers. The knee post-TKR was flexed-extend...

متن کامل

Conversion of patellofemoral arthroplasty to total knee arthroplasty

BACKGROUND AND PURPOSE The long-term outcome of patellofemoral arthroplasty is related to progression of femorotibial osteoarthritis with need for conversion to total knee arthroplasty. We investigated whether prior patellofemoral arthroplasty compromises the results of total knee arthroplasty. METHODS 13 patients who had had 14 Richards type II patellofemoral arthroplasties converted to tota...

متن کامل

The influence of malrotation and femoral component material on patellofemoral wear during gait.

Complications involving the patellofemoral joint, caused by malrotation of the femoral component during total knee replacement, are an important cause of persistent pain and failure leading to revision surgery. The aim of this study was to determine and quantify the influence of femoral component malrotation on patellofemoral wear, and to determine whether or not there is a difference in the ra...

متن کامل

Averaging rotational landmarks during total knee arthroplasty reduces component malrotation caused by femoral asymmetry

BACKGROUND Femoral component malrotation is a common cause of patient dissatisfaction after total knee arthroplasty. The sulcus line (SL) is more accurate than Whiteside's line as it corrects for variation in the coronal orientation of the groove. The hypothesis is that averaging the SL and posterior condylar axis (PCA) will reduce femoral malrotation. METHODS The component was inserted at a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical orthopaedics and related research

دوره 356  شماره 

صفحات  -

تاریخ انتشار 1998