Improvement in DMSA imaging using adaptive noise reduction: an ROC analysis.

نویسندگان

  • Lisa Lorimer
  • Howard G Gemmell
  • Peter F Sharp
  • Fergus I McKiddie
  • Roger T Staff
چکیده

Dimercaptosuccinic acid imaging is the 'gold standard' for the detection of cortical defects and diagnosis of scarring of the kidneys. The Siemens planar processing package, which implements adaptive noise reduction using the Pixon algorithm, is designed to allow a reduction in image noise, enabling improved image quality and reduced acquisition time/injected activity. This study aimed to establish the level of improvement in image quality achievable using this algorithm. Images were acquired of a phantom simulating a single kidney with a range of defects of varying sizes, positions and contrasts. These images were processed using the Pixon processing software and shown to 12 observers (six experienced and six novices) who were asked to rate the images on a six-point scale depending on their confidence that a defect was present. The data were analysed using a receiver operating characteristic approach. Results showed that processed images significantly improved the performance of the experienced observers in terms of their sensitivity and specificity. Although novice observers showed significant increase in sensitivity when using the software, a significant decrease in specificity was also seen. This study concludes that the Pixon software can be used to improve the assessment of cortical defects in dimercaptosuccinic acid imaging by suitably trained observers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparisons of Hounsfield Unit Linearity between Images Reconstructed using an Adaptive Iterative Dose Reduction (AIDR) and a Filter Back-Projection (FBP) Techniques

Background: The HU linearity is an essential parameter in a quantitative imaging and the treatment planning systems of radiotherapy. Objective: This study aims to evaluate the linearity of Hounsfield unit (HU) in applying the adaptive iterative dose reduction (AIDR) on CT scanner and its comparison to the filtered back-projection (FBP).Material and Methods: In this experimental phan...

متن کامل

Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

متن کامل

Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

متن کامل

Shearlet-Based Adaptive Noise Reduction in CT Images

The noise in reconstructed slices of X-ray Computed Tomography (CT) is of unknown distribution, non-stationary, oriented and difficult to distinguish from main structural information. This requires the development of special post-processing methods based on the local statistical evaluation of the noise component. This paper presents an adaptive method of reducing noise in CT images employing th...

متن کامل

Effect of Edge-Preserving Adaptive Image Filter on Low-Contrast Detectability in CT Systems: Application of ROC Analysis

OBJECTIVE For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As reported in previous studies, edge-preserving adaptive image filters, which selectively eliminate only the noise elements that are increased when the radiation dose is reduced without affecting the sharpness of images, have been developed. In the present ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nuclear medicine communications

دوره 33 11  شماره 

صفحات  -

تاریخ انتشار 2012