Corneal confocal microscopy is a rapid reproducible ophthalmic technique for quantifying corneal nerve abnormalities

نویسندگان

  • Alise Kalteniece
  • Maryam Ferdousi
  • Safwaan Adam
  • Jonathan Schofield
  • Shazli Azmi
  • Ioannis Petropoulos
  • Handrean Soran
  • Rayaz A Malik
چکیده

PURPOSE To assess the effect of applying a protocol for image selection and the number of images required for adequate quantification of corneal nerve pathology using in vivo corneal confocal microscopy (IVCCM). METHODS IVCCM was performed in 35 participants by a single examiner. For each participant, 4 observers used a standardized protocol to select 6 central corneal nerve images to assess the inter-observer variability. Furthermore, images were selected by a single observer on two occasions to assess intra-observer variability and the effect of sample size was assessed by comparing 6 with 12 images. Corneal nerve fiber density (CNFD), branch density (CNBD) and length (CNFL) were quantified using fully automated software. The data were compared using the intra class correlation coefficient (ICC) and Bland-Altman agreement plots for all experiments. RESULTS The ICC values for CNFD, CNBD and CNFL were 0.93 (P<0.0001), 0.96 (P<0.0001) and 0.95 (P<0.0001) for inter-observer variability and 0.95 (P<0.0001), 0.97 (P<0.001) and 0.97 (P<0.0001) for intra-observer variability. For sample size variability, ICC values were 0.94 (P<0.0001), 0.95 (P<0.0001), and 0.96 (P<0.0001) for CNFD, CNBD and CNFL. Bland-Altman plots showed excellent agreement for all parameters. CONCLUSIONS This study shows that implementing a standardized protocol to select IVCCM images results in high intra and inter-observer reproducibility for all corneal nerve parameters and 6 images are adequate for analysis. IVCCM could therefore be deployed in large multicenter clinical trials with confidence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid automated diagnosis of diabetic peripheral neuropathy with in vivo corneal confocal microscopy.

PURPOSE To assess the diagnostic validity of a fully automated image analysis algorithm of in vivo confocal microscopy images in quantifying corneal subbasal nerves to diagnose diabetic neuropathy. METHODS One hundred eighty-six patients with type 1 and type 2 diabetes mellitus (T1/T2DM) and 55 age-matched controls underwent assessment of neuropathy and bilateral in vivo corneal confocal micr...

متن کامل

Confocal microscopy of corneal sub-basal nerve plexus: a quantitative and qualitative analysis in healthy and pathologic eyes.

PURPOSE To validate corneal sub-basal nerve plexus examination by in vivo corneal confocal microscopy. METHODS Five parameters of corneal sub-basal nerve plexus in 250 human eyes (nerve fiber length, number of fibers, number of beadings, branching pattern, fiber tortuosity) acquired using in vivo corneal confocal microscopy (Confoscan 4.0; NIDEK Co Ltd) were analyzed. The first operator repea...

متن کامل

Corneal confocal microscopy is efficient, well-tolerated, and reproducible.

In order to develop an efficient, reproducible, and well-tolerated protocol for assessing corneal innervation, 11 normal subjects underwent corneal confocal microscopy (CCM) using a Heidelberg Retinal Tomography III microscope. Five standardized locations were sampled in the left eye and one centrally in the right. The protocol was repeated 1-4 weeks later. A blinded technician measured nerve f...

متن کامل

From the bedside to the bench and back again, with corneal confocal microscopy.

In this issue of IOVS, Davidson and colleagues apply a range of conventional techniques and the novel ophthalmic technique of corneal confocal microscopy (CCM) to phenotype nerve damage in an experimental model of prediabetes and type 2 diabetes. The key findings are that CCM allows a noninvasive demonstration of an early reduction in corneal innervation that correlates with a reduction in both...

متن کامل

Clinical applications of corneal confocal microscopy

Corneal confocal microscopy is a novel clinical technique for the study of corneal cellular structure. It provides images which are comparable to in-vitro histochemical techniques delineating corneal epithelium, Bowman's layer, stroma, Descemet's membrane and the corneal endothelium. Because, corneal confocal microscopy is a non invasive technique for in vivo imaging of the living cornea it has...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017