Biomechanical analysis of tension band wiring (TBW) of transverse fractures of patella

نویسندگان

  • Mohammed Ali
  • Jan Kuiper
  • Joby John
چکیده

PURPOSE Tension band wiring is commonly used for fixation of simple transverse fractures. The popular configuration is parallel Kirschner wires (K-wires) and a stainless steel wire loop placed in a vertically oriented figure-of-8. METHODS We used a wooden model of a patella with a midway transverse fracture and compared four different types of fixation. The first construct had a vertical figure-of-8 with one twist of wire. The second contained a vertical figure-of-8 with two twists of wire. The third was a vertical figure-of-8 with two twists of wire placed at adjacent corners while the last one had a horizontal figure-of-8 with two twists of wire placed at adjacent corners. Interfragmentary compression at the point of wire breakage was measured for each construct as well as permanent displacement on cyclic loading. RESULTS Placement of the figure-of-eight in a horizontal orientation with two wire twists at the corner improved interfragmentary compression by 63% (p < 0.05, Tukey post hoc test). On cyclic loading, all the constructs with vertical figure-of-eight but none with a horizontal construct failed (p=0.01; Fisher's exact test). Permanent fracture displacement after cyclic loading was 67% lower with horizontal figure- of-eight constructs (p < 0.05; t test). CONCLUSION Placing wire twists at the corner and a horizontal placement of figure-of-8 improves stability of the construct.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Use of Dual Reconstruction Plates for Failed Fixation of Patellar Fracture after Total Knee Replacement: A Case Report

Patellar fracture after total knee replacement (TKR) is one of the challenging problems in periprosthetic fracture. Open reduction with internal fixation (ORIF), as tension band wiring (TBW), usually required in cases with extensor mechanism disruption. However, many studies reported a high failure rate after using this technique. In this report, we presented an interesting case of periprosthet...

متن کامل

Percutaneous tension band wiring for patellar fractures.

PURPOSE To evaluate outcome of percutaneous tension band wiring for transverse fractures of the patella. METHODS 16 men and 7 women aged 27 to 65 (mean, 40) years underwent percutaneous tension band wiring for transverse fractures of the patella with a displacement of >3 mm. Pain, operating time, mobility, functional score, and complications were evaluated. RESULTS 20 patients underwent suc...

متن کامل

Rehabilitation of Isolated Patella Fracture: A Case Report

Fracture of the patella is a common injury among adults having higher prevalence among males population. The mechanism of injury involves direct and indirect mechanisms. The most common fracture pattern occurring is the transverse fracture followed by comminuted and vertical fractures. Treatment of patellar fractures depends on fracture type, integrity of extensor mechanism and size of fragment...

متن کامل

Internal Fixation of Transverse Patella Fractures Using Cannulated Cancellous Screws with Anterior Tension Band Wiring

Aims: To evaluate the effectiveness and safety of anterior tension band wiring technique using two cannulated cancellous screws in patients with transverse (AO34-C1) or transverse with mildly comminuted (AO34-C2) patellar fractures. Materials and Methods: This is a prospective study of 25 patients with transverse fracture or transverse fracture with mildly comminuted patella fractures. All the ...

متن کامل

A Prospective Randomised Control Trial for Comparison Between olecranon Lock Plate And Tension Band Wiring In Transverse olecranon Fractures

Introduction: Olecranon fractures are frequently encountered in the practice of orthopaedic surgery with a prevalence of 60% among patients with a fracture of the proximal ulna. Generally the treatment of choice for displaced olecranon fracture is open reduction and internal fixation. We report the result of a prospective Randomised Control Trial of Forty patients, who were treated either by Te...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2016