Design, development and validation of a new laryngo-pharyngeal endoscopic esthesiometer and range-finder based on the assessment of air-pulse variability determinants
نویسندگان
چکیده
BACKGROUND Laryngo-pharyngeal mechano-sensitivity (LPMS) is involved in dysphagia, sleep apnea, stroke, irritable larynx syndrome and cough hypersensitivity syndrome among other disorders. These conditions are associated with a wide range of airway reflex abnormalities. However, the current device for exploring LPMS is limited because it assesses only the laryngeal adductor reflex during fiber-optic endoscopic evaluations of swallowing and requires a high degree of expertise to obtain reliable results, introducing intrinsic expert variability and subjectivity. METHODS We designed, developed and validated a new air-pulse laryngo-pharyngeal endoscopic esthesiometer with a built-in laser range-finder (LPEER) based on the evaluation and control of air-pulse variability determinants and on intrinsic observer variability and subjectivity determinants of the distance, angle and site of stimulus impact. The LPEER was designed to be capable of delivering precise and accurate stimuli with a wide range of intensities that can explore most laryngo-pharyngeal reflexes. RESULTS We initially explored the potential factors affecting the reliability of LPMS tests and included these factors in a multiple linear regression model. The following factors significantly affected the precision and accuracy of the test (P < 0.001): the tube conducting the air-pulses, the supply pressure of the system, the duration of the air-pulses, and the distance and angle between the end of the tube conducting the air-pulses and the site of impact. To control all of these factors, an LPEER consisting of an air-pulse generator and an endoscopic laser range-finder was designed and manufactured. We assessed the precision and accuracy of the LPEER's stimulus and range-finder according to the coefficient of variation (CV) and by looking at the differences between the measured properties and the desired values, and we performed a pilot validation on ten human subjects. The air-pulses and range-finder exhibited good precision and accuracy (CV < 0.06), with differences between the desired and measured properties at <3 % and a range-finder measurement error of <1 mm. The tests in patients demonstrated obtainable and reproducible thresholds for the laryngeal adductor, cough and gag reflexes. CONCLUSIONS The new LPEER was capable of delivering precise and accurate stimuli for exploring laryngo-pharyngeal reflexes.
منابع مشابه
Maximum Maintainability of Complex Systems via Modulation Based on DSM and Module Layout.Case Study:Laser Range Finder
The present paper aims to investigate the effects of modularity and the layout of subsystems and parts of a complex system on its maintainability. For this purpose, four objective functions have been considered simultaneously: I) maximizing the level of accordance between system design and optimum modularity design,II) maximizing the level of accessibility and the maintenance space required,III...
متن کاملDevelopment and validation of a practical model for quantitative assessment of HSE performance of municipalities using the impact of urban management system components
Introduction: Throughout the world, many efforts have been made to provide suitable tools for achieving sustainable urban development and the achievement of a sustainable city. Establishing a Health, Safety and Environment Management System (HSE-MS) is one of the tools for achieving sustainable urban development. Measuring the performance of an organization in the HSE area is a precondition for...
متن کاملA Fully Integrated Range-Finder Based on the Line-Stripe Method
In this paper, an imaging chip for acquiring range information using by 0.35 μm CMOS technology and 5V power supply has been described. The system can extract range information without any mechanical movement and all the signal processing is done on the chip. All of the image sensors and mixed-signal processors are integrated in the chip. The design range is 1.5m-10m with 18 scales.
متن کاملManaging Automotive Product Development
The new product development (NPD) is the process by which a new product idea is conceived, investigated, taken through the design process, manufactured, marketed and serviced. In Automotive Engineering these related to the product realization process (PRP) which consists of five phases: "Plan and Define Program", "Product Design and Development", "Process Design and...
متن کاملDevelopment and Validation of the Determinants of Childbearing Intention Questionnaire Based on Theory of Planned Behavior in Iranian Women
Background and purpose: In today's world, declining fertility rates have led most high- and middle-income countries to pursue pronatalist policies. To plan for fertility desire and intention, it is necessary to examine their determinants in different societies. The purpose of this study was to design and evaluate the validity and reliability of a questionnaire that could measure the components...
متن کامل