Effect on Mechanical Properties of Orthodontic Elastomeric Ligatures on Immersion in Disinfecting Solutions - an in vitro Study
نویسنده
چکیده
Background and Objectives: Cold water disinfection can damage the elastomeric material, cross contamination in handling elastomeric ligatures is a serious concern in the orthodontic office. In addition, elastomeric strips with enough ligatures for both arches of a single patient are produced by most manufacturers. Thus, cross -contamination can occur in remaining ligatures if an entire strip is not used at once. In this investigation effect on tensile strength on short to medium exposure of elastomeric ligatures to disinfection solution and in turn its effect on force delivery is studied. Aims and Objectives: Effect of extended exposure to disinfection solutions on tensile load at failure of different orthodontic elastomeric ligatures is assessed. Materials and Methods: Orthodontic elastomeric ligatures were obtained from 5 manufacturers; 3M Unitek, Ormco, Ortho organizer, GAC, T P Orthodontics. 3 Disinfectant solutions used were Glutarex-3M Unitek, Cidex-Johnson and Johnson and Cidex OPAJohnson and Johnson. From each manufacturer, ten orthodontic elastomeric ligatures will be exposed to each disinfectant solution with exposure times of 30 minutes, 1 hour, 12 hour and 24 hours. Ten unexposed Original Research Article Singh; BJMMR, 18(4): 1-9, 2016; Article no.BJMMR.28630 2 elastomeric ligatures from each manufacturer will also be tested which will act as control group. Ligatures were stretched in custom made jig of a universal testing machine (INSTRON) until they fractured to determine the tensile load failure. Maximum tensile load were recorded. The tensile load at failure was used as an analog to the clinical situation of the ligature breakage during tie-in. Results and Conclusions: Three-way ANOVA showed significant differences (P < .0001) not only within manufacturer and time of exposure but also between disinfectants (P < .001). Significant interactions (P < .0001) were observed between manufacturer and time and between disinfectant and time. Greater significant changes were seen in tensile load at failure for all 5 manufactures ligatures in Cidex solution whereas changes were less significant in Glutarex and Cidex OPA solution. The ligatures from all companies showed significantly different failure loads from each other, with the ligatures from 3M exhibiting the greatest tensile load at failure and those from Ortho Organizer, the least. Elastomeric Ligatures Tensile Load at Failure Followed the Pattern: 3M Unitek _ GAC _ Ormco _ T P Orthodontics _ Ortho organizer. Tensile load to failure of elastomeric ligatures, compared to unexposed specimens changed when exposed to disinfectant solution for as little as 30 minutes.
منابع مشابه
Comparing Streptococcus Mutans Adhesion by Using Different Orthodontic Bracket Ligations: An In Vitro Study
Introduction: Orthodontic treatments and brackets application with various ligature methods have increased worldwide, but the growth rate and mechanism of microorganism adhesion to these ligatures is not fully discovered. The current study aimed to compare the level of streptococcus mutans adhesion to three different ligation methods. Materials and Methods: This in vitro study was performed on...
متن کاملAntimicrobial Effect of Zataria Multiflora Extract in Comparison with Chlorhexidine Mouthwash on Experimentally Contaminated Orthodontic Elastomeric Ligatures
OBJECTIVES Long-term use of orthodontic appliances and fixation ligatures creates a favorable environment for the accumulation of oral normal microflora and increases the risk of enamel demineralization and periodontal disease. The aim of this study was to compare the antimicrobial effects of Zataria Multiflora extract and 0.2% chlorhexidine (CHX) mouthwash on experimentally contaminated orthod...
متن کاملAnalysis of the Influence of Food Colorings in Esthetic Orthodontic Elastomeric Ligatures
PROPOSITION The purpose of this study was to evaluate in vitro the color changes of esthetic orthodontic elastomeric ligatures of different shades when exposed to four food colorings commonly found in the diet of patients. MATERIALS AND METHODS The sample consisted of esthetic orthodontic elastomeric ligatures in the colors pearl, pearl blue, pearl white and colorless, which were immersed for...
متن کاملSuperficial morphology and mechanical properties of in vivo aged orthodontic ligatures.
INTRODUCTION The degradation of elastic ligatures in the oral environment results in the need of periodic replacement to maintain the optimal force during the orthodontic treatment. The purpose of this study was to perform a clinical prospective randomized study of the degradation of orthodontic elastomeric ligatures in the oral environment by scanning electron microscopy (SEM) and tensile stre...
متن کاملFrictional resistance of orthodontic wires tied with 3 types of elastomeric ligatures.
The aims of this study were to determine and compare frictional resistance obtained by low-friction and conventional elastomeric ligatures in the presence of artificial saliva, and observe whether this variable changed after 21 days. Super Slick® low-friction elastomeric ligatures and conventional ligatures of the brands TP conventional® and Unitek® were placed on standard edgewise maxillary ce...
متن کامل