Impedance cardiography: a useful and reliable tool in optimization of cardiac resynchronization devices.

نویسندگان

  • Konstantin M Heinroth
  • Marcel Elster
  • Sebastian Nuding
  • Frithjof Schlegel
  • Arnd Christoph
  • Justin Carter
  • Michael Buerke
  • Karl Werdan
چکیده

AIMS Optimizing cardiac resynchronization therapy (CRT) devices has become more complex since modification of both atrioventricular (AV) and interventricular (VV) stimulation intervals has become possible. The current paper presents data from the routine use of impedance cardiography (IC)-based cardiac output (CO) measurements to guide the optimization of AV- and VV-interval timing of CRT devices. METHODS AND RESULTS Forty-six patients with heart failure (left ventricular ejection fraction <35%, New York Heart Association (NYHA) III-IV) and left bundle branch block (>130 ms) in sinus rhythm were evaluated 3-5 days after implantation of a CRT device by means of IC. CO was measured without pacing and with biventricular pacing using a standard protocol of VV- and AV-interval modification from -60 to +60 ms and 80 to 140 ms, respectively, in 20 ms steps. Mean CO without pacing was 3.66 +/- 0.85 L/min and significantly increased to 4.40 +/- 1.1 L/min (P<0.05) with simultaneous biventricular pacing and an AV interval of 120 ms. 'Optimizing' both VV and AV intervals further increased CO to 4.86 +/- 1.1 L/min (P<0.05). Maximum CO was measured in most patients with left ventricular pre-excitation. The proportion of 'non-responders' to CRT was reduced by 56% following AV- and VV-interval modification using IC guidance. CONCLUSION Modification of both AV and VV intervals in patients with a CRT device significantly improves CO compared with standard simultaneous biventricular pacing and no pacing. IC is a useful non-invasive technique for guiding this modification. Marked variability of optimal AV and VV intervals between patients requires optimization of these intervals for each patient individually.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the measured pre-ejection periods and left ventricular ejection times between echocardiography and impedance cardiography for optimizing cardiac resynchronization therapy

BACKGROUND The pre-ejection period (PEP) and left ventricular ejection time (LVET) are easily measured by impedance cardiography (ICG). We hypothesized that the PEP/LVET measured by ICG would correlate with that measured by echocardiography, and that PEP/LVET measured by ICG would be useful for cardiac resynchronization therapy (CRT) optimization. METHODS Newly CRT implanted patients were opt...

متن کامل

Measurement precision in the optimization of cardiac resynchronization therapy.

BACKGROUND Cardiac resynchronization therapy improves morbidity and mortality in appropriately selected patients. Whether atrioventricular (AV) and interventricular (VV) pacing interval optimization confers further clinical improvement remains unclear. A variety of techniques are used to estimate optimum AV/VV intervals; however, the precision of their estimates and the ramifications of an impr...

متن کامل

Whether noninvasive optimization of AV and VV delays improves the response to cardiac resynchronization therapy.

BACKGROUND Device optimization is not routinely performed in patients who underwent cardiac resynchronization therapy (CRT) device implantation. Noninvasive optimization of CRT devices by measurement of cardiac output (CO) can be used as a simple method to assess ventricular systolic performance. The aim of this study was to assess whether optimization of atrioventricular (AV) and interventricu...

متن کامل

Comparison of two Cardiac Output Monitors, qCO and LiDCO, during General Anesthesia

Background: Optimization of cardiac output (CO) has been evidenced to reduce postoperative complications and to expedite the recovery. Likewise, CO and other dynamic cardiac parameters can describe the systemic blood flow and tissue oxygenation state and can be useful in different clinical fields. This study aimed to validate the qCO monitor (Quantium Medical, Barcelona, Spain), a new device to...

متن کامل

Atrioventricular and interventricular delay optimization and response quantification in biventricular pacing: arrival of reliable clinical algorithms and research protocols, and how to distinguish them from unreliable counterparts.

In this issue of the journal, Bogaard et al. assess the achievable haemodynamic increment within individuals of optimizing atrioventricular (AV) and interventricular (VV) delays. Biventricular pacing, or cardiac resynchronization therapy (CRT), arguably the greatest advancement in the treatment of heart failure in the last decade, causes immediate increases in haemodynamics and then improvement...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 9 9  شماره 

صفحات  -

تاریخ انتشار 2007