Heterotrophic plate counts and the isolation of bacteria from mineral waters on selective and enrichment media.

نویسندگان

  • C M Manaia
  • O C Nunes
  • P V Morais
  • M S da Costa
چکیده

The heterotrophic plate counts of 15 brands of bottled non-carbonated mineral waters were examined and found to be generally high and variable. Four selective or enrichment media for the enumeration of coliforms (m-Endo LES and m-lauryl sulphate agar) and Pseudomonas aeruginosa (cetrimide-nalidixic acid agar and malachite green broth) were used to isolate several species of Gram-negative bacteria. Strains identified as CDC gr IVc-2 and Comamonas (Ps.) acidovorans were the two most commonly isolated. Considerable variation in populations was seen between the brands, as well as between two batches of the same mineral water.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved methods for the enumeration of heterotrophic bacteria in bottled mineral waters.

At this time the European Union regulations require that the heterotrophic plate counts (HPC) of mineral waters be assessed at two recovery temperatures: 22 degrees C for 72 h and 37 degrees C for 24 h. This procedure is time consuming and expensive. Development of new rapid methods for microbiological assessment of the microbial flora in the bottled water is an industry-driven need. The object...

متن کامل

Bacteriological and chemical evaluation of overseas mineral waters.

Overseas and imported mineral waters were subjected to visual examination, tested for standard plate count and heterotrophic bacteria, and also analyzed to determine the concentrations of several anions and cations. Some products showed turbidity or color, and several had standard plate count and/or heterotrophic bacteria. One imported natural mineral water product had a high level of standard ...

متن کامل

باکتری‌های هتروتروف در آب آشامیدنی شهر تبریز

Background and Aim: Recently the use of heterotrophic plate count (HPC) has received much attention as a supplementary indicator of the MPN test in water quality control. The US Environmental Protection Agency (USEPA) has declared 500 cfu/mL as the maximum acceptable level for heterotrophic bacteria in distribution networks. Currently the HPC determination is not among the routine control items...

متن کامل

A survey of heterotrophic bacteria and coliforms in the water of old and new distribution networks

Controlling the microbiological quality of water is important for its uses. Microbiological requirements of drinking water ensure the absence of coliforms, but may indicate the potential presence of other potentially pathogenic microorganisms and viruses of fecal origin. A total of 36 water samples, representing the drinking water of the whole city of Aradan, Semnan, Iran, were randomly collect...

متن کامل

Comparison of Six Culture Methods for Salmonella Isolation from Poultry Fecal Samples

Abstract Background and Objective: Salmonellosis is one of the most important food-borne bacterial zoonotic diseases worldwide, and poultry and its products are the major sources for salmonella transmission to human. Isolation of Salmonellaenterica from poultry needs bacteriologic enrichment and selected cultures of fecal samples. In this study, different culture methods for the isolation of s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of applied bacteriology

دوره 69 6  شماره 

صفحات  -

تاریخ انتشار 1990