16 channel, Bell Shaped Surface Coil for Knee Imaging
نویسندگان
چکیده
Introduction: Whole-volume surface coils have been demonstrated to deliver a high signal to noise ratio (SNR) in the near-surface region of the sample volume without diminution of the SNR in the center. In recent years, several musculo-skeletal MRI studies have ventured into the development of high channel count coils (> 4 elements) for knee imaging [1]. A 16-channel whole-volume coil array consisting of 16 surface coil elements has been reported in literature [2]. However, the performance of these coil arrays has been limited by the amount of vicinal (adjacentadjacent) overlap of the coil array elements; one cannot increase geometric overlap of these circular coils beyond the geometric flux coupling null. Here we propose a novel coil configuration for 1.5 Tesla imaging and coil element (Bell shaped-coil, which the authors dub as bell-loop) ; it will be demonstrated that using such a shape of array element allows significantly greater vicinal overlap whilst maintaining the desired flux nulling. The base of the bell-loop is purposefully tapered, so that adjacent element overlap occurs only in the parallel sided region. It will be shown that the bell loop also exhibits the advantage of greater penetration depth compared to a simple loop coil of equivalent aperture. Due to very limited commercial availability of 16 channel knee coils, we evaluated the performance of the proposed coil array with that of a custom made 16-channel coil array with standard rectangular design elements. Experimental and simulation results with cylindrical phantoms are presented that demonstrate the high central SNR and rapid peripheral SNR rolloff of the design, two intrinsic benefits of the bell coil relative to the current art of loop coils. Materials and Methods: Fig 1 illustrates the array design for both the cases. Adjacent bell-loop elements were overlapped to null mutual inductance. The bell loop coil pairs were organized into two adjoined concentric rings of eight elements; the rings were wrapped around a cylinder of length 21cm and 14 cm dia wrapped with foam to make the outer dia 21 cm. To compare the SNR experimentally, images of the same cylindrical knee phantom ( relative permittivity = 72 and conductivity = 0.75 S/m) were acquired for both the arrays. 16-channel acquisition system (GE Excite, 1.5T) was used and a fast spin echo sequence was used with a TE of 14 ms, a TR of 500 ms and FOV of 24cm. The body coil was used to transmit signal for both the cases. The simulation of the coil was performed using finite element method based full-wave 3D electromagnetic simulation of the coil model, and post processing of the computed field. For exporting the field values from the tool, the volume of dielectric load (which approximates phantom or human anatomy Knee) was decomposed into voxel dimension of 5mmX5mmX5mm. The complex coil sensitivity (B1-map) S, was calculated using tangential magnetic fields, Si = -(Hy(i) jHx(i))/2. SNR = ∑i((Si* Rn*conj(Si) )), where Rn noise correlation matrix .
منابع مشابه
A 16 Channel Radio Frequency Anterior Neck Coil for Imaging of the Cervical Carotid Bifurcation
Introduction Disease of the cervical carotid artery occurs primarily in the region of the cervical carotid bifurcation and is a major source of embolic stroke. Although MRI may be the best method for imaging and characterizing the individual risk of the disease, imaging the disease is hampered by the small size of the plaque morphology, the variable position and depth of the artery in many subj...
متن کامل96-Channel receive-only head coil for 3 Tesla: design optimization and evaluation.
The benefits and challenges of highly parallel array coils for head imaging were investigated through the development of a 3T receive-only phased-array head coil with 96 receive elements constructed on a close-fitting helmet-shaped former. We evaluated several designs for the coil elements and matching circuitry, with particular attention to sources of signal-to-noise ratio (SNR) loss, includin...
متن کاملScalable multichannel MRI data acquisition system.
A scalable multichannel digital MRI receiver system was designed to achieve high bandwidth echo-planar imaging (EPI) acquisitions for applications such as BOLD-fMRI. The modular system design allows for easy extension to an arbitrary number of channels. A 16-channel receiver was developed and integrated with a General Electric (GE) Signa 3T VH/3 clinical scanner. Receiver performance was evalua...
متن کاملAssessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کامل