Treatment of titanium dental implants with three piezoelectric ultrasonic scalers: an in vivo study.

نویسندگان

  • Hideyuki Kawashima
  • Shuichi Sato
  • Mamoru Kishida
  • Hiroaki Yagi
  • Kazuma Matsumoto
  • Koichi Ito
چکیده

BACKGROUND Dental implants require regular maintenance. It is crucial that the instrument used for maintenance be able to remove plaque and calculus from the implant surface effectively and efficiently, while causing minimal damage to its circumference. Some ultrasonic scalers may be useful for implant maintenance; however, no clinical study has examined this. This study evaluated the treatment of titanium implants with three piezoelectric scalers in vivo. METHODS Fourteen patients underwent implant treatment in which plaque and calculus were removed from the abutment surfaces with ultrasonic scalers. The abutments were treated with scalers with carbon (VS; N = 7), plastic (PS; N = 7), or metallic (ES; N = 7) tips. The abutment surface characteristics were examined after instrumentation using scanning electron microscopy. The amount of plaque remaining and roughness were estimated using a modification of the remaining plaque and calculus score and the modified roughness score, respectively. In addition, the abutment surfaces were imaged with a laser profilometer and a laser scanning electron microscope (SEM). RESULTS The remaining plaque and calculus scores did not differ significantly among the VS, PS, and ES groups. VS and PS produced a significantly smoother abutment surface than ES. The laser SEM three-dimensional images also demonstrated that VS and PS produced smooth abutment surfaces, whereas ES resulted in damaged surfaces. CONCLUSIONS VS and PS produced clean, smooth abutment surfaces. Piezoelectric scalers with non-metal tips are suitable for use in dental implant maintenance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasonic scaler oscillations and tooth-surface defects.

Damage to tooth root surfaces may occur during ultrasonic cleaning with both piezoelectric and magnetostrictive ultrasonic scalers. It is unclear which mechanism causes more damage or how their mechanism of action leads to such damage. Our null hypothesis is that tooth-surface defect dimensions, resulting from instrumentation with ultrasonic scalers, are independent of whether the scaler probe ...

متن کامل

Ultramorphology of the root surface subsequent to hand-ultrasonic simultaneous instrumentation during non-surgical periodontal treatments. An in vitro study

OBJECTIVE The purpose of this study was to investigate the ultramorphology of the root surfaces induced by mechanical instrumentation performed using conventional curettes or piezoelectric scalers when used single-handedly or with a combined technique. MATERIAL AND METHODS Thirty single-rooted teeth were selected and divided into 3 groups: Group A, instrumentation with curettes; Group B instr...

متن کامل

Thermal and Surface Changes of Dental Implants Following Use of Rotary Instruments and Piezoelectric Devices for Implantoplasty: An In-Vitro Study

  Objective: Peri-implantitis is an irreversible inflammatory reaction in the soft and hard tissues around a functional implant . One of the treatment approaches of this disease include smoothing and polishing the rough surface and removing threads on the implants using rotary instruments, which is called implantoplasy. Clinicians should perform implantoplasty with caution because it may raise ...

متن کامل

Patients' perception of pain during ultrasonic debridement: a comparison between piezoelectric and magnetostrictive scalers.

PURPOSE To compare patients' perception of discomfort, vibration and noise levels between piezoelectric and the magnetostrictive ultrasonic units during periodontal debridement. METHODS Periodontal debridement was performed on 75 subjects using a split-mouth design. Two quadrants on the same side were instrumented with a piezoelectric ultrasonic device (EMS Swiss Mini Master® Piezon) and the ...

متن کامل

Sampling water from chemically cleaned dental units with detachable power scalers.

UNLABELLED Power toothbrushes (PTBs), in combination with abrasive dentifrices, may encourage wear of dental cements at crown margins. PURPOSE This study's purpose was to determine the effect chemical cleaning had on the microbial quality of water emitted from dental unit waterlines (DUWL), 3-way syringes, and power scalers. METHODS Ten randomly selected dental units with attached self-cont...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of periodontology

دوره 78 9  شماره 

صفحات  -

تاریخ انتشار 2007