Effects of sex on the incidence of cardiac tamponade after catheter ablation of atrial fibrillation: results from a worldwide survey in 34 943 atrial fibrillation ablation procedures.
نویسندگان
چکیده
BACKGROUND Cardiac tamponade is the most dramatic complication observed during atrial fibrillation (AF) ablation and the leading cause of procedure-related mortality. Female sex is a known risk factor for complications during AF ablation; however, it is unknown whether women have a higher risk of tamponade. METHODS AND RESULTS A systematic Medline search was used to locate academic electrophysiological centers that reported cases of tamponade occurring during AF ablation. Centers were asked to provide information on cases of acute tamponade according to sex and their mode of management including any case of related mortality. Nineteen electrophysiological centers provided information on 34 943 ablation procedures involving 25 261 (72%) men. Overall, 289 (0.9%) cases of tamponade were reported: 120 (1.24%) in women and 169 (0.67%) in men (odds ratio, 1.83; P<0.001). There was a reciprocal association between center volume and the occurrence of tamponade with substantially lower risk in high-volume centers. Most cases of tamponade occurred during catheter manipulation or ablation; women tended to develop more tamponades during transseptal catheterization. No sex difference in the mode of management was observed. However, 16% cases of tamponade required surgery with lower rates in high-volume centers. Three cases of tamponade (1%) culminated in death. CONCLUSIONS Tamponade during AF ablation procedures is relatively rare. Women have an ≈2-fold higher risk for developing this complication. The risk of tamponade among women decreases substantially in high-volume centers. Surgical backup and acute management skills for treating tamponade are important in centers performing AF ablation.
منابع مشابه
Effect of Oral Anticoagulant Therapy on Coagulation Activity and Inflammatory Markers in Patients with Atrial Fibrillation Undergoing Ablation: A Randomized Comparison between Dabigatran and Warfarin
Atrial fibrillation (AF) is associated with inflammatory and hypercoagulability state. Previous studies evaluated the safety and efficacy of dabigatran and warfarin in prevention of thrombothic complications. This study was intended to assess the influence of these drugs on hemostatic and inflammatory markers among patient underwent pulmonary vein ablation. A total of 100 patients with AF w...
متن کاملEffect of Oral Anticoagulant Therapy on Coagulation Activity and Inflammatory Markers in Patients with Atrial Fibrillation Undergoing Ablation: A Randomized Comparison between Dabigatran and Warfarin
Atrial fibrillation (AF) is associated with inflammatory and hypercoagulability state. Previous studies evaluated the safety and efficacy of dabigatran and warfarin in prevention of thrombothic complications. This study was intended to assess the influence of these drugs on hemostatic and inflammatory markers among patient underwent pulmonary vein ablation. A total of 100 patients with AF w...
متن کاملEffects of Sex on the Incidence of Cardiac Tamponade After Catheter Ablation of Atrial Fibrillation
Catheter ablation of atrial fibrillation (AF) is one of the most complex interventional procedures in cardiology. The procedure has been associated with a minimal but nevertheless important risk of major complications. Cardiac tamponade is the most frequently encountered procedure-related complication occurring in 1.2% to 1.3% of patients in 2 worldwide surveys and 1.3% in a European survey. It...
متن کاملEffects Of Fast Pathway Ablation On The Concealment Zone And Electrophysiological Behavior Of AV-Node During Atrial Fibrillation.
Objectives: Dual pathways have a determinant role in the occurrence of atrio nodal tachyarrhythmia (AVNRT). The aim of present study is to determine the role of slow pathway (SP) in the concealment zone and protective role of AV node during atrial fibrillation (AF). Material &Methods: In 7 isolated nodal rabbit preparation zone of concealment and concealed conduction is quantified by Specif...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 7 2 شماره
صفحات -
تاریخ انتشار 2014