Comparison of multiplex immunoassay platforms.

نویسندگان

  • Qin Fu
  • Jie Zhu
  • Jennifer E Van Eyk
چکیده

BACKGROUND Candidate biomarkers discovered with high-throughput proteomic techniques (along with many biomarkers reported in the literature) must be rigorously validated. The simultaneous quantitative assessment of multiple potential biomarkers across large cohorts presents a major challenge to the field. Multiplex immunoassays represent a promising solution, with the potential to provide quantitative data via parallel analyses. These assays also require substantially less sample and reagents than the traditional ELISA (which is further limited by its ability to measure only a single antigen). We have measured the reproducibility, reliability, robustness, accuracy, and throughput of commercially available multiplex immunoassays to ascertain their suitability for serum biomarker analysis and validation. METHODS Assay platforms MULTI-ARRAY (Meso Scale Discovery), Bio-Plex (Bio-Rad Laboratories), A(2) (Beckman Coulter), FAST Quant (Whatman Schleicher & Schuell BioScience), and FlowCytomix (Bender MedSystems) were selected as representative examples of technologies currently used for high-throughput immunoanalysis. All assays were performed according to protocols specified by the manufacturers and with the reagents (diluents, calibrators, blocking reagents, and detecting-antibody mixtures) included with their kits. RESULTS The quantifiable interval determined for each assay and antigen was based on precision (CV < 25%) and percentage recovery (measured concentration within 20% of the actual concentration). The MULTI-ARRAY and Bio-Plex assays had the best performance with the lowest limits of detection, and the MULTI-ARRAY system had the most linear signal output over the widest concentration range (10(5) to 10(6)). Cytokine concentrations in unspiked and cytokine-spiked serum samples from healthy individuals were further investigated with the MULTI-ARRAY and Bio-Plex assays. CONCLUSIONS The MULTI-ARRAY and Bio-Plex multiplex immunoassay systems are the most suitable for biomarker analysis or quantification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Antibody-based protein multiplex platforms: technical and operational challenges.

BACKGROUND The measurement of multiple protein biomarkers may refine risk stratification in clinical settings. This concept has stimulated development of multiplexed immunoassay platforms that provide multiple, parallel protein measurements on the same specimen. CONTENT We provide an overview of antibody-based multiplexed immunoassay platforms and discuss technical and operational challenges....

متن کامل

MicroArray System: an open platform for multiplex immunoassay development

Multiplexing Assays The introduction of the microarray with its ability to globally interrogate a sample for a multitude of factors (e.g. gene expression monitoring; biomarker discovery) has quickly brought us to a new testing paradigm. The advent of “omics” driven parallel processing for quantitative biology has created new opportunities for assay development. Most attractive are turn-key plat...

متن کامل

Validation Processes of Protein Biomarkers in Serum—A Cross Platform Comparison

Due to insufficient biomarker validation and poor performances in diagnostic assays, the candidate biomarker verification process has to be improved. Multi-analyte immunoassays are the tool of choice for the identification and detailed validation of protein biomarkers in serum. The process of identification and validation of serum biomarkers, as well as their implementation in diagnostic routin...

متن کامل

Meso Scale Discovery and Luminex Comparative Analysis of Calbindin D28K

The sensitivity of different renal regions to xenobiotics requires the development of a multiplex immunoassay for the simultaneous analysis of kidney biomarkers. Calbindin D28K is a distal tubule-specific protein that can be detected in urine under pathological conditions. In this study, a pair of anti-calbindin D28K antibodies was used in an immunoassay for the detection of calbindin D28K expr...

متن کامل

Accuracy and reproducibility of a multiplex immunoassay platform: a validation study.

BACKGROUND Multiplex immunoassays offer many advantages over singleplex assays for the analysis of multiple analytes in a single sample. We sought to validate a specific multiplex cytokine immunoassay (Human 9-plex cytokine array on the Searchlight® platform by Thermoscientific) prior to use in a large clinical study. METHODS We compared spike and recovery of recombinant proteins on the Searc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 56 2  شماره 

صفحات  -

تاریخ انتشار 2010