A new supraglottic airway, the Elisha Airway Device: a preliminary study.

نویسندگان

  • Sonia J Vaida
  • Diana Gaitini
  • Bruce Ben-David
  • Mostafa Somri
  • Carin A Hagberg
  • Luis A Gaitini
چکیده

We describe the Elisha Airway Device (EAD), a new reusable supraglottic ventilatory device. Its uniqueness consists of its ability to combine three functions in a single device: ventilation, blind and/or fiberoptic-aided intubation without interruption of ventilation, and gastric tube insertion. This study was performed in 70 ASA status I-II, Mallampati class I-II patients undergoing elective knee arthroscopy and receiving general anesthesia with mechanical ventilation. Anesthesia was induced with fentanyl and propofol and was maintained with isoflurane in N20/oxygen. Neuromuscular blockade was achieved with vecuronium. Blind insertion of the device was successful in 96% of patients, with a mean insertion time of 20 +/- 4 s. In these patients it was possible to maintain oxygenation and ventilation throughout the surgical procedure. Gastric tube insertion was successful in all cases. Endotracheal intubation via the EAD was attempted in 20 patients. Blind intubation was possible during the first and second attempts in 15 and 2 patients, respectively. Fiberoptic intubation was then successful in two of the remaining three patients. The EAD is a new alternative in the evolution of supraglottic ventilatory devices; however, further clinical studies are necessary to evaluate its efficacy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries

Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...

متن کامل

A New Method for Removal of Supraglottic Leech Infestation, an Unusual Cause of Hemoptysis.

Foreign bodies in upper airway may have various presentations and be life threatening. Leeches can attach to upper airway and cause serious problems. Herein we report a 55-year-old man with hemoptysis due to attachment of leech and explain our technique for its removal.

متن کامل

A preliminary assessment of the LMA protector™ in non-paralysed patients

BACKGROUND The LMA Protector™ is the latest CE marked single use supraglottic airway device. This airway device provides access and functional separation of the respiratory and digestive tracts. There are two ports (male, female ports) to provide suction in the laryngeal region and insertion of the gastric tube. The aim of our study is to assess the ease of use, airway quality, device positioni...

متن کامل

Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices.

We evaluated the performance of four currently available manikins: Airway Management Trainer (Ambu, UK), Airway Trainer (Laerdal, Norway), Airsim (Trucorp, Ireland), 'Bill 1' (VBM, Germany), with eight supraglottic airway devices: Airway Management Device, Cobra Perilaryngeal Airway, Combitube, i-Gel, Laryngeal Tube, Laryngeal Tube Disposable, Laryngeal Tube Suction II and Streamlined Liner of ...

متن کامل

The optimum sevoflurane concentration for supraglottic airway device Blockbuster™ insertion with spontaneous breathing in obese patients: a prospective observational study

BACKGROUND Airway management of the obese patient presenting for surgery is more likely to be a challenging problem. Supraglottic airway device has been adopted as a bridge to connect ventilation and tracheal intubation in obese patients who would be suffered with difficult intubation. The optimum sevoflurane concentration for supraglottic airway device insertion allowing spontaneous breathing ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 99 1  شماره 

صفحات  -

تاریخ انتشار 2004