Validity of transcutaneous oxygen/carbon dioxide pressure measurement in the monitoring of mechanical ventilation in stable chronic respiratory failure.
نویسندگان
چکیده
The accuracy and precision of transcutaneous pressure measurements of oxygen (Ptc,O2) and carbon dioxide (Ptc,CO2) in the monitoring of nocturnal assisted ventilation in adult patients were evaluated. Transcutaneous measurements obtained with two analysers, Radiometer TINATCM3 (R) and Kontron MicroGas-7650 (K), were compared with arterial blood gases analysed in blood samples withdrawn simultaneously in 10 patients. Sensors were heated to 43 degrees C. Measurements of transcutaneous blood gases and arterial blood gases were collected six times at 1-h intervals. The data obtained with both instruments were similar and did not significantly change over the 5 h test period. Measurement of Ptc,O2 underestimated arterial oxygen tension (Pa,O2) and this underestimation increased with the level of Pa,O2 (p<0.01). Measurements of Ptc,CO2 overestimated arterial carbon dioxide tension (Pa,CO2) and this overestimation increased with the level of Pa,CO2 (p<0.05). These errors suggested an instrumental bias. Mathematical correction of this bias neutralized the error in accuracy and improved the precision (SD of the differences transcutaneous blood gases - arterial blood gases). An additional correction, suppressing the between-subject scattering, improved the actual precision: precision was reduced from 1.9 to 0.8 kPa (14.4 to 5.7 mmHg) (R) and from 1.7 to 0.5 kPa (13.1 to 3.7 mmHg) (K) for oxygen, and from 1.0 kPa (7.8 mmHg) (R) and 0.7 kPa (5.6 mmHg) (K) to 0.4 kPa (3.2 mmHg) for carbon dioxide (R and K). In conclusion, with these two successive corrections, transcutaneous oxygen and carbon dioxide provide a reliable estimation of blood gases to monitor nocturnal ventilation in adults with chronic respiratory failure.
منابع مشابه
Comparison of the Effects of Open and Closed Endotracheal Suction on Cardiovascular and Ventilation Parameters for Patients Undergoing Mechanical Ventilation
Background and Objectives: Suction is a necessary and common method which aids in the release of secretion from the respiratory system for the patients who have undergone mechanical ventilation. One of the most common complications of suction is hypoxemia which causes dysrhythmia and death. The purpose of this study was to determine the effects of open and closed-endotracheal suction on cardiov...
متن کاملNoninvasive monitoring of oxygen and carbon dioxide.
New technologies for the noninvasive assessment of oxygen and carbon dioxide are transforming clinical practice. Transcutaneous monitoring of PO2 (PtcO2) and PCO2 (PtCO2) provides an approximation of PaO2 and PaCO2 values in hemodynamically normal individuals, but both PtcO2 and PtcCO2 diverge from the corresponding arterial values when cardiac output is reduced, even in the absence of hypotens...
متن کاملEarly Effectiveness of Noninvasive Positive Pressure Ventilation on Right Ventricular Function in Chronic Obstructive Pulmonary Disease Subjects with Acute Hypercapnic Respiratory Failure
Introduction: Noninvasive positive pressure ventilation (NIPPV) has become an integral tool in the management of acute hypercapnic respiratory failure (AHRF) in chronic obstructive pulmonary disease (COPD). This study was performed to evaluate the early effects of NIPPV on pulmonary artery pressure (PAP), serum N-terminal pro BNP (NT-proBNP), and ventilatory parameters in the COPD patients with...
متن کاملMask intermittent positive pressure ventilation in chronic hypercapnic respiratory failure due to chronic obstructive pulmonary disease.
Noninvasive ventilation in chronic obstructive pulmonary disease (COPD) has been shown to improve arterial blood gases but its long-term role has not been established. We retrospectively studied 26 consecutive patients with hypercapnic ventilatory failure due to COPD in whom oxygen therapy caused worsening hypercapnia (defined as a rise in the daytime arterial carbon dioxide tension (Pa,CO2) to...
متن کاملConcordance between side-stream end-tidal carbon dioxide and arterial carbon dioxide partial pressure in respiratory service setting
Non-invasive monitoring of arterial oxygen using percutaneous pulse oximetry is well established. Although some studies show a good correlation of transcutaneous end-tidal carbon dioxide partial pressure (PetCO2) with arterial carbon dioxide partial pressure (PaCO2), they were performed in research settings and involved restricted populations such as paediatric, accident and emergency, or inten...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 13 5 شماره
صفحات -
تاریخ انتشار 1999