Triazole Susceptibilities in Thermotolerant Fungal Isolates from Outdoor Air in the Seoul Capital Area in South Korea

نویسندگان

  • Seungeun Lee
  • Siyu Xu
  • Chemmeri Padasseri Bivila
  • Hyeyoung Lee
  • Myung Soo Park
  • Young Woon Lim
  • Naomichi Yamamoto
  • Kap-Hoon Han
چکیده

Emerging fungi resistant to triazoles are a concern because of the increased use of medical triazoles and exposure to agricultural triazoles. However, little is known about the levels of triazole susceptibility in outdoor airborne fungi making it difficult to assess the risks of inhalation exposure to airborne, antifungal-resistant fungi. This study examined triazole susceptibilities of the airborne thermotolerant fungi isolated from the ambient air of the Seoul Capital Area of South Korea. We used impactor air sampling with triazole-containing nutrient agar plates as the collection substrates to screen for airborne fungal isolates based on their triazole susceptibilities. This study estimated that 0.17% of all the culturable fungi belong to the pathogenic thermotolerant taxa, among which each isolate of Aspergillus niger and Aspergillus tubingensis showed a minimum inhibitory concentration (MIC) of 2 μg/mL or greater for itraconazole. Their concentration in air was 0.4 CFU/m3. Seven human pathogenic Paecilomyces variotii isolates had MICs of 32 μg/mL or greater and lower than 2 μg/mL for the agricultural fungicide tebuconazole and the medical triazole itraconazole, respectively. Though the concentration was low, our results confirm the presence of airborne fungi with high MICs for itraconazole in ambient air. Inhalation is an important exposure route because people inhale more than 10 m3 of air each day. Vigilance is preferred over monitoring for the emergence of triazole-resistant fungal pathogens in ambient outdoor air.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose distribution evaluation of various dose calculation algorithms in inhomogeneous media

Background: Dose calculation algorithms play a very important role in predicting the explicit dose distribution. We evaluated the percent depth dose (PDD), lateral depth dose profile, and surface dose volume histogram in inhomogeneous media using calculation algorithms and inhomogeneity correction methods. Materials and Methods: The homogeneous and inhomogeneous virtual slab phantoms used in th...

متن کامل

Examining the effectiveness of initial response training program for nuclear emergency preparedness

Background: Although nuclear technology has various beneficial, it also has a variety of risks. In particular, initial response is very import to respond to risks. Therefore, the program to increase initial response proficiency can be regarded as very essential. The Republic of Korea annually conducts more than 10 nuclear emergency response training programs, and specialized training courses f...

متن کامل

Impact of outdoor air pollution on the incidence of tuberculosis in the Seoul metropolitan area, South Korea

BACKGROUND/AIMS Although indoor air pollution is a well-known risk factor for tuberculosis (TB), the possible link between outdoor air pollution and TB development has not been examined fully. We assessed the impact of outdoor air pollution on TB development in the Seoul metropolitan area, South Korea. METHODS The mean concentrations of ambient particulate matter (PM) with an aerodynamic diam...

متن کامل

Radioactivity of surface soils from Oyo state, South Western Nigeria

Background: The activity concentrations of some radionuclides in soil samples collected from 20 locations in 8 major towns in Oyo State, Southwestern Nigeria have been determined by gamma-ray spectrometry technique. Materials and Methods: The activity concentrations were determined using high-purity germanium (HPGe) detector (Canberra Industries Inc.). The outdoor absorbed dose rates in air at ...

متن کامل

Dosimetric accuracy of the Acuros XB and Anisotropic analytical algorithm near interface of the different density media for the small fields of a 6- MV flattening-filter-free beam

Background: This study was conducted to assess the accuracy of dose calculation near the air-phantom interface of a heterogeneous phantom for Acuros XB (AXB) and Anisotropic Analytical Algorithm (AAA) algorithm of a           6-MV flattening-filter-free beam, compared with film measurements. Materials and Methods: A phantom included air gap was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015