Low-cost digital subtraction angiography.

نویسندگان

  • K K Ford
  • E R Heinz
  • G A Johnson
  • B D Drayer
  • P J Dubois
چکیده

Intravenous angiography was an important diagnostic tool earlier in th is century [1] , however, the technique had many drawbacks . Film timing was critical, the volume of contrast material was high , and the contrast resolution was often poor. When safer techniques for direct arteriography were developed, intravenous angiography was abandoned . Computed digital image processing has brought a resurgence of interest in intravenous angiography [2-1 3]. The enhanced contrast resolution of th is technique approaches the contrast resolution of direct arteriography and requires smaller volumes of contrast material than the older techniques of intravenous angiography. In addition, it can be performed on an outpatient basis. Several systems capable of performing digital intravenous angiography are commercially available, with prices of $150,000-$500,000. We are investigating the clinical application of a digital intravenous angiography system with capital equipment costs of about $50,000 . The system is designed around a Quantex OS-20 (Quantex Corp ., Sunnyvale, Cal.) digital image processor. The basic components of our system and the results of some preliminary investigations are presented .

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Digital subtraction cerebral angiography by intraarterial injection: comparison with conventional angiography.

For 4 months, a prototype digital subtraction system was used to obtain images of the cerebral vasculature after intraarterial contrast injections. In 12 instances, the intraarterial injections were recorded with both a digital subtraction unit and conventional direct magnification film-screen system. The digital subtraction and conventional film subtraction images were compared and graded for ...

متن کامل

Low-dose Contrast-enhanced Magnetic Resonance Angiography with Less than the Standard Dose of Gadolinium Chelate: Comparison with Conventional Digital Subtraction Angiography

angiography, various performance enhancing MR sequences and scanning protocols have been adopted (17). The development of higher performance MR scanners has facilitated these trials (5, 8, 9), and contrast-enhanced MR angiography (CEMRA) has thus become a feasible method of vascular imaging. Various amounts of contrast media have been used for CEMRA, ranging from the standard dose of 0.05 mmol ...

متن کامل

3D contrast-enhanced MRA of the runoff vessels: value of image subtraction

Introduction: Diagnostic accuracy and cost will determine the success of contrast-enhanced 3D MRA in replacing catheter-based digital subtraction angiography (DSA) as the modality of choice for assessing the peripheral run-off arteries. Image subtraction, proposed by some investigators as a way to enhance diagnostic accuracy (1) lengthens data acquisition and post-processing times and therefore...

متن کامل

Impact of digital subtraction angiography on carotid evaluation.

Impact of digital subtraction angiography by intravenous injection (DSAV) was examined in a private neurology clinic. In the evaluation of threatened stroke, advent of DSAV was associated with reduced use of both traditional noninvasive tests (from 100% of patients to 36%), and conventional arteriograms (from 29% to 4%). Less compelling indications were often prescreened with noninvasive tests;...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 3 4  شماره 

صفحات  -

تاریخ انتشار 1982