Effect of Pupil Size on Flicker ERGs Recorded With RETeval System: New Mydriasis-Free Full-Field ERG System.

نویسندگان

  • Kumiko Kato
  • Mineo Kondo
  • Masahiko Sugimoto
  • Kengo Ikesugi
  • Hisashi Matsubara
چکیده

PURPOSE We studied whether pupil size affects the flicker electroretinograms (ERGs) recorded by RETeval, a new mydriasis-free full-field flicker ERG system. METHODS We studied 10 healthy subjects. The RETeval manufacturer claims that the system delivers a constant flash retinal illuminance by adjusting the flash luminance to compensate for changes in the pupil size. Two experiments were performed. First, the flicker ERG was recorded every 3 minutes after the instillation of mydriatics. Second, the flicker ERG was recorded while the subjects wore soft contact lenses with two different artificial pupil sizes. RESULTS The first experiment showed that as pupil size increased, the amplitudes of the fundamental component of the flicker ERG did not change significantly, but the implicit times of the fundamental component were significantly prolonged for larger pupil sizes. There was a significant positive correlation between the pupillary area and implicit time of the fundamental component (r = 0.93, P < 0.001). The second experiment showed that the implicit times of the fundamental component in the flicker ERG were significantly longer with larger artificial pupil. CONCLUSIONS The results suggest that the effective retinal illuminance of the stimulus delivered by the RETeval system decreases for large pupil sizes. However, in most clinical testing situations, patients' undilated pupils will likely be sufficiently small to fall within the range for which the system delivers a stimulus of constant retinal illuminance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Screening for diabetic retinopathy using new mydriasis-free, full-field flicker ERG recording device

Diabetic retinopathy (DR) is a leading cause of blindness among working-age adults. Therefore, it is important to detect DR accurately during mass screening. The purpose of this study was to determine whether a small, hand-held, mydriasis-free, full-field flicker electroretinographic (ERGs) device called RETeval can be used to screen for DR. To accomplish this, we recorded full-field flicker ER...

متن کامل

Flicker electroretinograms of eyes with cataract recorded with RETeval system before and after mydriasis

Purpose The aim of this study is to determine the effect of pupil size of eyes with cataracts on the flicker electroretinograms (ERGs) elicited and recorded with the RETeval system. Patients and methods Forty-one eyes of 41 patients (mean age, 76.5±7.3 years) that had grade 2 nuclear or cortical cataract without any other abnormalities were studied. Flicker ERGs were recorded before and after...

متن کامل

Factors Affecting Mydriasis-Free Flicker ERGs Recorded With Real-Time Correction for Retinal Illuminance: Study of 150 Young Healthy Subjects.

Purpose A small, full-field flicker electroretinogram (ERG) recording system was recently developed to record flicker ERGs without mydriasis (RETeval). The device delivers a stimulus with constant retinal illuminance by adjusting the retinal luminance to compensate for changes in the pupillary area. The purpose of this study was to determine what factors affect the fundamental components of the...

متن کامل

Effects of cataracts on flicker electroretinograms recorded with RETeval™ system: new mydriasis-free ERG device

BACKGROUND The purpose of this study was to evaluate the effects of cataracts on the flicker electroretinograms (ERGs) recorded with the RETeval™ system under mydriatic-free conditions. METHODS This was a retrospective study of 82 eyes of 60 patients with cataracts and 52 eyes of 38 patients who were pseudophakic. Flicker ERGs were recorded with the RETeval™ system (LKC Technologies, Gaithers...

متن کامل

Evaluation of cone function by a handheld non-mydriatic flicker electroretinogram device

PURPOSE Full-field electroretinograms (ERGs) are used to evaluate retinal function in patients with various types of hereditary and acquired retinal diseases. However, ERG recordings require relatively invasive procedures, including pupillary dilation and the use of contact lens electrodes. Thus, it would be helpful to have a simpler and noninvasive screening method. The purpose of this study w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 56 6  شماره 

صفحات  -

تاریخ انتشار 2015