Correlation between intradialytic hypotension in patients undergoing routine hemodialysis and use of acetate compared in bicarbonate dialysate.

نویسندگان

  • M Thaha
  • M Yogiantoro
  • Soewanto
  • Pranawa
چکیده

AIM To determine the incidence of intradialytic hypertension (IDH) during hemodialysis (HD) in end-stage renal disease (ESRD) patients using acetate dialysate compared to those using bicarbonate dialysate. METHODS This study was a double-blind cross-over randomized clinical trial. The effect of acetate and bicarbonate dialysate on blood pressure was analyzed in two consecutive HD sessions. The selected subjects were 41 stable ESRD patients scheduled for dialysis 2 times/week/from the HD unit of Dr.Soetom Hospital Surabaya, aged between 21-65 years old, with a hemoglobin level > or = 7 g/dL, serum albumin > or = 3 mg/dL and interdialytic weight gain < 4 Kg, and an average Qb 150-250 ml/minute. The dialysate sodium level was 138 mEq/L/ The study subjects were divided into tow groups: 21 patients in the group who received Acetate on the first session and Bicarbonate on the next (AB) and 20 patients in the group receiving Bicarbonate first (BA). Comparison of IDH during use of each dialysate was analyzed by Chi-Square and Mc Nemar Chi-Square test. RESULTS No characteristic differences were found in both groups: HD duration (for AB) was 28.83 +/- 13.89 vs. 34.95 +/- 24.80 months (for BA) (p = 0.333); Age (for AB) was 47.61 +/- 9.49 vs. 47.75 +/- 11.80 years (for BA) (p = 0.969); Hemoglobin (Hb) level (for AB) 8.19 +/- 0.84 vs. 7.94 +/- 0.41 mg/dL (for BA) (p = 0.238); serum Albumin (for AB) was 3.79 +/- 0.26 vs. 3.82 +/- 0.30 g/dl (for BA) (p = 0.652). The number of patients with IDH during acetate dialysate with IDH during bicarbonate dialysate was 1 (2.4%). Overall, there were 11 patients with Diabetic Kidney Disease (26.8%). Six out of them (54.5%) had IDH during acetate dialysate and only and 1 patient (9.1%) had IDH during acetate and bicarbonate. CONCLUSION The incidence of IDH in hemodialysis using acetate is significantly greater than that when bicarbonate is used (p = 0.000).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparision between effects of bicarbonate and acetate dialysates on spirometry parameters in patients with chronic renal failure undergoing hemodialysis

Introduction: Chronic renal failure causes impairment of all body organs including heart and lungs. Main problem in these patients are pulmonary edema due to increased permeability of capillaries, intravascular and interstitial volume overload, hypertension and heart failure. These changes cause altered physiologic and mechanical function of lungs. The objective of this study is evaluating the ...

متن کامل

تأثیر به‌کارگیری محلول دیالیز سرد بر افت فشارخون حین همودیالیز در بیماران مبتلا به مرحله آخر نارسایی کلیه

Background: Hypotension is the most frequent adverse event during hemodialysis. Cool dialysate is a simple and cost effective measure in treating intradialytic hypotension by stabilization of core body temperature. This study was designed to find out the effects of cool dialysate on the frequency of intradialytic hypotension, presenting symptoms and intervention measures used for patients under...

متن کامل

اثر نوع محلول بافر همودیالیز در کنترل فشارخون و کفایت دیالیز بیماران همودیالیزی مزمن

Background: The effect of kind of dialysis solution on the control of blood pressure and adequacy and efficacy of hemodialysis is a most debated and controversial issue. Methods: Twenty six chronic hemodialized patients in Ghaem hemodialysis center, Mashhad, Iran, in winter of the year 2004, enrolled this study for one month. The patients were dialyzed with bicarbonate buffer and were dialy...

متن کامل

The Effect of the Type of Hemodialysis Buffer on the QTc Interval in Patients on Chronic Hemodialysis

Background: Identifying the sources of variation in QTc measurements is important for preventing arrhythmias during and after hemodialysis. The present study was designed to determine the correlation between the type of hemodialysis buffer and the changes in QTc interval in patients on chronic hemodialysis. Methods: Fifty-nine patients on chronic hemodialysis who referred in winter 2007 to hemo...

متن کامل

بررسی تاثیر تغییر غلظت سدیم محلول دیالیز همراه با تغییر سرعت اولترافیلتراسیون بر افت فشارخون حین دیالیز و وزن بین جلسات دیالیز

Background and purpose:Intradialytic hypotension (IDH) is the most frequent complicationin patients receiving haemodialysis (HD) that poses most problems for patient and treatment team. The use of sodiumprofile and ultra filtration (UF) profile is one of the preventive methods that have been recently introduced. However, increased intradialytic weight gain (IDWG) has been described as the sid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta medica Indonesiana

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 2005