Quantification of area at risk during coronary occlusion and degree of myocardial salvage after reperfusion with technetium-99m methoxyisobutyl isonitrile.

نویسندگان

  • A J Sinusas
  • K A Trautman
  • J D Bergin
  • D D Watson
  • M Ruiz
  • W H Smith
  • G A Beller
چکیده

Serial myocardial imaging with technetium-99m methoxyisobutyl isonitrile (99mTc-MIBI) has been proposed for evaluating myocardial salvage after reperfusion. To define 99mTc-MIBI uptake before and after reperfusion, 17 open-chest dogs underwent 3 hours of left anterior descending artery occlusion and 3 hours of reperfusion. 99mTc-MIBI was injected during occlusion (group 1) or after 90 minutes of reperfusion (group 2). Myocardial 99mTc-MIBI activity was correlated with microsphere flow during occlusion and reperfusion. Anatomic risk area and infarct area were defined by postmortem vital staining and correlated with the perfusion defects defined by analysis of 99mTc-MIBI macroautoradiographs and gamma camera images of myocardial slices. The left ventricle was divided into 96 segments for gamma well counting. Flow and 99mTc-MIBI activity were normalized to nonischemic values. Myocardial segments were grouped, based on occlusion flow, into zones: severely ischemic (less than or equal to 30% nonischemic), moderately ischemic (greater than 30%, less than or equal to 60% nonischemic), mildly ischemic (greater than 60%, less than or equal to 90% nonischemic), and nonischemic (greater than 90%, less than or equal to 120% nonischemic). Among dogs injected with 99mTc-MIBI during coronary occlusion (group 1), myocardial 99mTc-MIBI activity correlated linearly with occlusion flow for both endocardial (r = 0.91) and transmural (r = 0.91) segments. The risk area defined by 99mTc-MIBI autoradiography (group 1) correlated with the postmortem risk area (rho = 0.94) but was 29% smaller than the anatomic risk area (p = 0.03), reflecting the contribution of collateral flow. Among dogs injected with 99mTc-MIBI after reperfusion (group 2), myocardial 99mTc-MIBI did not correlate with reperfusion flow in either endocardial or transmural segments. Among group 2 dogs, myocardial 99mTc-MIBI activity was significantly less than reperfusion flow at the time of injection in the severely ischemic (25 +/- 5% versus 74 +/- 24% nonischemic, p = 0.002), moderately ischemic (54 +/- 12% versus 96 +/- 15% nonischemic, p = 0.001), and mildly ischemic (84 +/- 6% versus 93 +/- 3% nonischemic, p = 0.002) zones. The defect area defined by 99mTc-MIBI autoradiography (group 2) correlated very closely with the postmortem infarct area (rho = 0.98). Thus, the myocardial uptake of 99mTc-MIBI during coronary occlusion correlates with occlusion flow and reflects the "area at risk." When 99mTc-MIBI was given after 90 minutes of reperfusion following 3 hours of coronary occlusion, the myocardial activity was significantly reduced compared with reperfusion flow in both necrotic and perinecrotic regions, reflecting myocardial viability more than the degree of reperfusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial Salvage After Reperfusion With Technetium-99m Methoxyisobutyl Isonitrile

Serial myocardial imaging with technetium-99m methoxyisobutyl isonitrile (9'Tc-MIBI) has been proposed for evaluating myocardial salvage after reperfusion. To define 'mTc-MIBI uptake before and after reperfusion, 17 open-chest dogs underwent 3 hours of left anterior descending artery occlusion and 3 hours of reperfusion. 9'Tc-MIBI was injected during occlusion (group 1) or after 90 minutes of r...

متن کامل

Area-at-risk determination by technetium-99m-hexakis-2-methoxyisobutyl isonitrile in experimental reperfused myocardial infarction.

In a canine model of reperfused myocardial infarction, we tested the hypothesis that after reperfusion, technetium-99m-hexakis-2-methoxyisobutyl isonitrile (Tc-MIBI) tomographic imaging still reflects occlusion blood flow when the tracer is injected before reperfusion. Nine anesthetized dogs underwent 2 hours of coronary occlusion followed by 3 hours of reperfusion ending by being killed. Refer...

متن کامل

99mTc-sestamibi uptake and retention during myocardial ischemia and reperfusion.

BACKGROUND 99mTc-methoxyisobutyl isonitrile (Sestamibi) is a new perfusion agent that has shown promise for the noninvasive detection of myocardial salvage after coronary reperfusion in acute myocardial infarction. The objective of this study was to further validate that myocardial uptake and retention of Sestamibi after reperfusion in a canine myocardial infarction model are markers of tissue ...

متن کامل

Single Photon Emission Computed Tomography With Technetium-99m Hexakis 2~Methoxyisobutyl Isonitrile in Acute Myocardi~.I Infarction Before and After Thrombolytic Treatment: Assessment of Salvaged Myocardium and Prediction of Late Functional Recovery

Single photon emission computed tomography (SPECT) with technetium-99m hexakis 2-methoxyisobutyl isonitrile was investigated as a method to evaluate the results of intravenous thrombolytic treatment in 14 patients (11 men and 3 women) with acute myocardial infarction admitted to the coronary care unit within 4 h of the onset of symptoms. All patients received an injection of 740 MBq of the trac...

متن کامل

Calculation of Coronary Angiographic Total Blush in Patients with Coronary Artery Disease and its Prognostic Implication

BACKGROUND Myocardial perfusion grade (MPG) is an accepted method of evaluating myocardial perfusion. However, it does not take into the account, the extent of the perfusion. We hypothesized that myocardial blush area times MPG (total blush) would be more accurate than simple MPG, and yield better prognostic information. METHODS About 34 patients were recruited after they had consented to bot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 82 4  شماره 

صفحات  -

تاریخ انتشار 1990